Verified by manufacturer 3 months ago
Single leaf: Anodized.
Thermally broken aluminium commercial door system.
Suitable for use with medium-high traffic commercial new build and refurbishment projects.
Thermally broken aluminium commercial door system.
Features and benefits:
Color | Other Guidance for specification option: Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized Guidance for specification option: Anodized to a minimum 15 micrometres thickness. Polyester powder coated Guidance for specification option: Polyester powder coated to a minimum 60 micrometres thickness. Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee. |
Material | Aluminium Glass |
Shape | Rectangle |
Width | 1200 mm Guidance for specification option: Single door (tested limits). 1250 mm Guidance for specification option: Single door (hardware limits). 2000 mm Guidance for specification option: Double door (tested limits). 2500 mm Guidance for specification option: Double door (hardware limits). Manufacturer guidanceRecommended size limits (maximum). |
Height | 2200 mm Guidance for specification option: Single door (tested limits). Double door (tested limits). 2400 mm Guidance for specification option: Single door (hardware limits). Double door (hardware limits). Manufacturer guidanceRecommended size limits (maximum). |
Uniclass | |
CAWS | L10/56 Glazed screen system L10/560 Glazed screen system L20/480 Doorsets L20/55 Doorsets |
Product range |
Framing | |
Framing members | Aluminium curtain wall frame sections. |
Cladding units | |
Glass units | Glass panels.Guidance for specification option: 24—40 mm glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing. Glazing.Guidance for specification option: 24—40 mm insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.Guidance for specification option: 24—40 mm insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Panels and facings | |
Material | Aluminium infill panels. |
System accessories | Not required.GT659.Guidance for specification option: Single ramp low threshold. GT660.Guidance for specification option: Low threshold. GT661.Guidance for specification option: Double ramp low threshold. Midrail.Guidance for specification option: Insert requirements. Sidelight.Guidance for specification option: Insert requirements. Fanlight.Guidance for specification option: Insert requirements. |
Execution | Curtain wall assembly and erection. |
System completion | Verification of performance. |
Product Reference | AluK GT55 TB Thermally Broken Commercial Door System |
Outer frame | GT202. Guidance for specification option: Deep pocket frame. GT211. Guidance for specification option: Sill frame. GT320. Guidance for specification option: DB transom. GT324. Guidance for specification option: Header bar. GT325. Guidance for specification option: Auto door header bar. |
Vent | GT524. Guidance for specification option: Anti-finger trap adaptor. GT600. Guidance for specification option: Standard top rail. GT604. Guidance for specification option: Standard bottom rail. GT620. Guidance for specification option: Locking stile. GT622. Guidance for specification option: Anti-finger trap hinge stile. |
Sub sill | Not required. GT218. Guidance for specification option: Standard sub sill. |
Configuration | Single, bi-directional - hold open. Single, bi-directional - non hold open. |
Type | Anodized. Guidance for specification option: To a minimum 15 micrometres thickness. Manufacturer guidanceFinish exterior. |
Texture | Not applicable. Manufacturer guidanceFinish exterior. |
Colour | Anodized. Manufacturer guidanceFinish exterior. |
Type | Anodized. Guidance for specification option: To a minimum 15 micrometres thickness. Manufacturer guidanceFinish interior. |
Texture | Not applicable. Manufacturer guidanceFinish interior. |
Colour | Anodized. Manufacturer guidanceFinish interior. |
Ironmongery | Electronic access locking. Guidance for specification option: Insert requirements. Electronic access panic door (Dorma). Guidance for specification option: Insert requirements. Manual locking. Guidance for specification option: Insert requirements. Panic door (Dorma). Guidance for specification option: Insert requirements. Panic door (Sentinel). Guidance for specification option: Insert requirements, not available with double door. |
FrameDepth | 110 mm. |
Bead | Square. |
Panel weight | 110 kg. Manufacturer guidanceRecommended weight limits (maximum): per leaf. |
Size: | 1250 x 2400 mm. Guidance for specification option: Recommended size limits (maximum): Single door (w x h): (hardware limits). 1200 x 2200 mm. Guidance for specification option: Recommended size limits (maximum): Single door (w x h): (tested limits). As schedule. Guidance for specification option: Insert requirements. As drawing. Guidance for specification option: Insert requirements. |
Country of product manufacture | United Kingdom |