Verified by manufacturer 2 months ago
Single leaf: Anodized.
An external glazed aluminium commercial ground floor door system.
Suitable for use with medium-high traffic commercial new build and refurbishment projects.
An external glazed aluminium commercial ground floor door system.
Features and benefits:
Color | Other Guidance for specification option: Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized Guidance for specification option: Anodized to a minimum 15 micrometres thickness. Polyester powder coated Guidance for specification option: Polyester powder coated to a minimum 60 micrometres thickness. Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee. |
Material | Aluminium Glass |
Shape | Rectangle |
Width | 1200 mm Guidance for specification option: Single leaf PAS24. 1250 mm Guidance for specification option: Single leaf. 2000 mm Guidance for specification option: Double leaf PAS24. 2500 mm Guidance for specification option: Double leaf. Manufacturer guidanceMaximum sizes. |
Height | 2200 mm Guidance for specification option: Double leaf. Double leaf PAS24. 2400 mm Guidance for specification option: Single leaf. Single leaf PAS24. Manufacturer guidanceMaximum sizes. |
Uniclass | |
CAWS | L10/56 Glazed screen system L10/560 Glazed screen system L20/480 Doorsets L20/55 Doorsets |
Product range |
Framing | |
Framing members | Aluminium curtain wall frame sections. |
Cladding units | |
Glass units | Glass panels.Guidance for specification option: 24—28 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing. Glazing.Guidance for specification option: 24—28 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.Guidance for specification option: 24—28 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Panels and facings | |
Material | Aluminium infill panels. |
System accessories | Not required.GT260.Guidance for specification option: Double ramp low threshold. GT261.Guidance for specification option: Single ramp low threshold. |
Execution | Curtain wall assembly and erection. |
System completion | Verification of performance. |
Product Reference | AluK GT55 NI Non-Thermally Broken Commercial Door System |
Outer frame | GT201. Guidance for specification option: Standard frame. GT203. Guidance for specification option: Frame GT207. Guidance for specification option: DB transom. GT210. Guidance for specification option: Sill frame. GT320. Guidance for specification option: Deep head frame. |
Vent | GT316. Guidance for specification option: Rebated door stile. GT500. Guidance for specification option: Standard top rail. GT504. Guidance for specification option: 120 mm bottom rail. GT505. Guidance for specification option: 180 mm bottom rail. GT520. Guidance for specification option: NI standard stile. |
Sub sill | Not required. GT218. Guidance for specification option: Standard sub sill. |
Configuration | Single. |
Glazing | Glass panels. Guidance for specification option: 24–28 mm glass look-a-like panels, insert requirements. Glazing. Guidance for specification option: 24–28 mm insulating glass units, insert requirements. Infill panels. Guidance for specification option: 24–28 mm insulated sandwich panels, insert requirements. |
Type | Anodized. Guidance for specification option: To a minimum 15 micrometres thickness. Manufacturer guidanceExternal finish. |
Texture | Not applicable. Manufacturer guidanceExternal finish. |
Colour | Anodized. Manufacturer guidanceExternal finish. |
Type | Anodized. Guidance for specification option: To a minimum 15 micrometres thickness. As exterior. Manufacturer guidanceInternal finish. |
Texture | Not applicable. Manufacturer guidanceInternal finish. |
Colour | Anodized. Manufacturer guidanceInternal finish. |
Ironmongery | Guidance for specification option: Insert manual locking requirements. |
FrameDepth | 110 mm. |
Bead | Square. |
Panel weight | 80 kg. Guidance for specification option: Recommended weight limits (maximum): per leaf. |
Size: | 1250 x 2400 mm. Guidance for specification option: Recommended size limits (maximum): Single door (w x h) (hardware limits). As drawing. As schedule. 1200 x 2200 mm Guidance for specification option: Maximum size. PAS24 option. |
Threshold | Manufacturers standard. Low threshold. Ramped threshold. |
Country of product manufacture | United Kingdom |