NBS Source
I'm a manufacturer
Compare variants

AluK 77IW Open In Window System

Verified by manufacturer 2 months ago

Bottom Hung Vent: Anodized.

AluK (GB) Ltd Variant:

Aluminium commercial open in casement window.

Jump to:
+44 (0)1291 639739 Website

Application

Suitable for use with high rise residential and commercial new build and refurbishment projects.

Description

Aluminium commercial open in casement window.


Features and benefits:

  • Windows project in and can be fully customized in terms of security, weather and functionality.
  • Dedicated groove for ethylene propylene diene monomer (EPDM) mounting.
  • Integrates with AluK curtain walling.
  • Windows are Secured by Design accredited and are Q-Marked in accordance with BS 4873 and PAS 24.
  • Aluminium profiles are extruded in accordance with BS EN 12020, and are manufactured from grade 6060/ 6063 T6 aluminium.
  • Compliant with ADL1/ ADL2 capable of achieving U-value of 1.2 W/m²K double glazing and 0.8 W/m²K triple glazing
  • A variety of powder coated colours are available in accordance with BS 6496 and BS EN 12206-1:2004.
  • Powder coating is applied to a Qualicoat standard, utilizing an inline flash anodizing pre-treatment process, with the polyester powder coating applied within 30 minutes of the flash anodizing process to ensure suitable adhesion.
  • Windows can be dual coloured, textured or have an anodized finish.

General information

Color

Other

Guidance for specification option:

Insert RAL colour requirement or type 'Not applicable' for anodized.

Finish

Anodized

Guidance for specification option:

To a minimum 15 micrometres thickness.

Powder-coated

Material

Aluminium

Shape

Rectangle

Width

77 mm

Manufacturer guidance

Recommended weight limits (maximum).

Height

-

Manufacturer guidance

Recommended weight limits (maximum).

Uniclass

Pr_30_59_98_02 Aluminium window unitsPrimary

CAWS

L10/25 Aluminium windows

L10/330 Aluminium windows

Product range

Casement Window

Specification data - Aluminium window units

Standard

Non-fire- and/ or smoke-rated windows to BS EN 14351-1.

Dimensions and configurations

Bottom hung vent.

Product performance

-

Weather performance

-

UK exposure category

To BS 6375-1.

Air permeability

Class 4 (600 Pa).

Watertightness

E1050 (1200 Pa).

Resistance to wind load

C5 (2000 Pa).

Safety

-

Security level

Secured By Design certification and to PAS 24.

Thermal

-

Whole window U-value

1.2 W/m²K double glazing; 0.8 W/m²K triple glazing.

Frame

-

Finish as delivered

-

Coating

Anodized.

Colour

Anodized.

Film thickness (minimum)

15 micrometres.

Ventilator

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Glazing or infill

-

Requirements

Glass panels.

Guidance for specification option:

24–50 mm glass look-a-like panels, insert requirements.


Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing.

Glazing.

Guidance for specification option:

24–50 mm insulating glass units, insert requirements.


Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door).

Infill panels.

Guidance for specification option:

24–50 mm insulated sandwich panels, insert requirements.


Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core.

Operation

-

Type

Manual.

Execution

Fixing of aluminium frames.

Outer frame

K2000.

Guidance for specification option:

53 mm frame.

K2003.

Guidance for specification option:

78 mm frame.

K2010.

Guidance for specification option:

71 mm deep frame.

K2013.

Guidance for specification option:

96 mm frame.

K2064.

Guidance for specification option:

Curtain wall insert.

Coupler

Not required.

U43650.

Guidance for specification option:

H coupler.

U43651.

Guidance for specification option:

38 mm coupler.

Sub sill

Not required.

U43631.

Guidance for specification option:

Sub sill.

Texture

Not applicable.

Ironmongery

Locking handle with a 1/3 sash position sash position.

Guidance for specification option:

Insert requirements.

Locking handle with a centre sash position.

Guidance for specification option:

Insert requirements.

Accessories

Not required.

809650.

Guidance for specification option:

Weathering centre seal.

K2029.

Guidance for specification option:

Threshold profile.

K2064.

Guidance for specification option:

Curtain wall insert adaptor.

U43630.

Guidance for specification option:

Reverse rebate adaptor.

Show more

Bead

Square.

Panel weight

80 kg.

Guidance for specification option:

Bottom hung.

Manufacturer guidance

Recommended weight limits (maximum).

Size:

1200 x 2400 mm.

Guidance for specification option:

Balcony door (w x h) (hardware limits).

2000 x 1200 mm.

Guidance for specification option:

Bottom hung (w x h) (hardware limits).

995 x 2200 mm.

Guidance for specification option:

Tilt before turn (w x h) (tested limits - sash size).

As drawing.

Guidance for specification option:

Insert reference.

As schedule.

Guidance for specification option:

Insert reference.

Manufacturer guidance

Recommended weight limits (maximum).

Sustainability data

Country of product manufacture

United Kingdom

Literature

AluK 77 Windows System Brochure

AluK 77 Windows System Brochure

AluK 77IW Open-In Window System Datasheet

AluK 77IW Open-In Window System Datasheet

Similar products from AluK (GB) Ltd

AluK 58BW Open In HI Thermally Broken Window System

AluK 58BW Open In HI Thermally Broken Window System

AluK 58BW Open Out HI Thermally Broken Window System

AluK 58BW Open Out HI Thermally Broken Window System

AluK 58BW SA Open In Thermally Broken Student Accommodation Window System

AluK 58BW SA Open In Thermally Broken Student Accommodation Window System

AluK 58BW ST HI Open Out Thermally Broken Heritage Window System

AluK 58BW ST HI Open Out Thermally Broken Heritage Window System

AluK 77IS Concealed Open In Thermally Broken Commercial Window System

AluK 77IS Concealed Open In Thermally Broken Commercial Window System

AluK 77IWE Open Out Window System

AluK 77IWE Open Out Window System

AluK C70S Open In Thermally Broken Window System

AluK C70S Open In Thermally Broken Window System

AluK C70S Open Out Thermally Broken Window System

AluK C70S Open Out Thermally Broken Window System