Bottom Hung Vent: Anodized.
Aluminium louvred panel and open in casement window.
Suitable for use in a variety of applications.
Aluminium louvred panel and open in casement window. The window system incorporates a bead glazed fixed louvre externally as part of the window outer frame only. Face fixed louvres cannot be used.
Features and benefits:
Color | Other Guidance for specification option: Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized Guidance for specification option: To a minimum 15 micrometres thickness. Polyester powder coated Guidance for specification option: Polyester powder coated to a minimum 60 micrometres thickness. Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee. |
Material | Aluminium Glass |
Shape | Rectangle |
Width | 2400 mm Guidance for specification option: Casement fixed light. 1725 mm Guidance for specification option: Tilt before turn sash (hardware limits). Tilt only sash (hardware limits). Turn only sash (hardware limits). 715 mm Guidance for specification option: Tilt before turn sash (tested limits). 1065 mm Guidance for specification option: Tilt before turn sash (tested limits - BS 4873 only). Manufacturer guidanceRecommended size limits (maximum). |
Height | 2400 mm Guidance for specification option: Casement fixed light. 2300 mm Guidance for specification option: Tilt before turn sash (hardware limits). Tilt only sash (hardware limits). Turn only sash (hardware limits). 1530 mm Guidance for specification option: Tilt before turn sash (tested limits). 2230 mm Guidance for specification option: Tilt before turn sash (tested limits - BS 4873 only). |
Uniclass | |
CAWS | L10/25 Aluminium windows L10/330 Aluminium windows |
Product range |
Dimensions and configurations | Bottom hung vent. |
Product performance | |
Weather performance | |
Air permeability | Class 3 (600 Pa). |
Watertightness | Class 8A (450 Pa). |
Resistance to wind load | E2400 (2400 Pa). |
Safety | |
Security level | Secured by designed certification and to PAS 24. |
Thermal | |
Whole window U-value | 1.6 W/m²K. |
Frame | |
Finish as delivered | |
Coating | Anodized. |
Colour | Anodized. |
Film thickness (minimum) | 15 micrometres. |
Ventilator | AW621.Guidance for specification option: Square vent. |
Glazing or infill | |
Requirements | Glass panels.Guidance for specification option: 28–40 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing. Glazing.Guidance for specification option: 28–40 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.Guidance for specification option: 28–40 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Operation | |
Type | Manual. |
Execution | Fixing of aluminium frames. |
Product Reference | AluK 58BW SA Open In Thermally Broken Student Accommodation Window System |
Texture | Not applicable. |
Ironmongery | Lifetime Homes manual vents. Guidance for specification option: Bottom sash position, insert requirements. Manual opening vents. Guidance for specification option: Centre sash position, insert requirements. |
Outer frame | AW695. Guidance for specification option: Louvre window frame. |
FrameDepth | 70 mm. |
Bead | Square. |
Panel weight | 100 kg. Guidance for specification option: Tilt before turn sash. 100 kg. Guidance for specification option: Tilt only sash. 100 kg. Guidance for specification option: Turn only sash. Manufacturer guidanceRecommended weight limits (maximum). |
Size: | As drawing. Guidance for specification option: Insert reference. As schedule. Guidance for specification option: Insert reference. Manufacturer guidanceRecommended size limits (maximum). |
Country of product manufacture | United Kingdom |
AluK 58BW Open In HI Thermally Broken Window System
AluK 58BW Open Out HI Thermally Broken Window System