Verified by manufacturer 3 months ago
Fixed Light: Anodized.
Aluminium open out casement window.
Suitable for use with residential new build and refurbishment projects.
Aluminium open out casement window.
Features and benefits:
Color | Other Guidance for specification option: Insert RAL colour requirement or type 'Not applicable' for anodized. |
Finish | Anodized Guidance for specification option: To a minimum 15 micrometres thickness. Polyester powder coated Guidance for specification option: Polyester powder coated to a minimum 60 micrometres thickness. Polyester powder coated to a minimum 60 micrometres thickness with marine environment guarantee. |
Material | Aluminium Glass |
Shape | Rectangle |
Size | Manufacturer guidanceRecommended size limits (maximum). |
Width | 1750 mm |
Height | 1750 mm |
Uniclass | |
CAWS | L10/25 Aluminium windows L10/330 Aluminium windows |
Product range |
Dimensions and configurations | Fixed light. |
Product performance | |
Weather performance | |
Air permeability | Class 3 (600 Pa). |
Watertightness | Class 8A (450 Pa). |
Resistance to wind load | E2400 (2400 Pa). |
Safety | |
Security level | Secured by design certification and to PAS 24. |
Thermal | |
Whole window U-value | 1.4 W/m²K. |
British Fenestration Rating Council Window Energy Rating | A.Guidance for specification option: In accordance with BFRC regulations including BS EN ISO 10077-2, 58BW Internal Glazed Commercial Windows can achieve: Window Energy Rating - ’A’. |
Frame | |
Finish as delivered | |
Coating | Anodized. |
Colour | Anodized. |
Film thickness (minimum) | 15 micrometres. |
Ventilator | Not required.AW610.Guidance for specification option: Externally glazed chamfered vent. AW611.Guidance for specification option: Externally glazed chamfered vent. AW613.Guidance for specification option: Externally glazed ovolo vent. AW616.Guidance for specification option: Internally glazed chamfered vent. AW618.Guidance for specification option: Internally glazed ovolo vent. AW620.Guidance for specification option: Internally glazed flat vent. AW624.Guidance for specification option: Externally glazed flat vent. |
Glazing or infill | |
Requirements | Glass panels.Guidance for specification option: 28–40 mm glass look-a-like panels, insert requirements. Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W Glazing.Guidance for specification option: 25–35 mm insulating glass units, insert requirements. Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door). Infill panels.Guidance for specification option: 25–35 mm insulated sandwich panels, insert requirements. Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core. |
Operation | |
Type | Manual. |
Execution | Fixing of aluminium frames. |
Product Reference | AluK 58BW Open Out Thermally Broken Window System |
Outer frame | AW600. Guidance for specification option: 70 mm chamfered slim frame. AW601. Guidance for specification option: 70 mm chamfered frame. AW602. Guidance for specification option: 70 mm standard ovolo frame. AW603. Guidance for specification option: 58 mm odd leg frame. AW604. Guidance for specification option: 58 mm slim frame. |
Bead | Chamfered. Square. |
Coupler | Not required. AW702. Guidance for specification option: 15 mm coupler, for 70 mm frame. AW703. Guidance for specification option: 15 mm coupler, for 58 mm frame. AW705. Guidance for specification option: 26 mm coupler, for 70 mm frame. AW706. Guidance for specification option: 26 mm coupler, for 58 mm frame. |
Sub sill | Not required. AW542. Guidance for specification option: 150 mm sill. AW543. Guidance for specification option: 177 mm sill. AW544. Guidance for specification option: 190 mm sill. AW570. Guidance for specification option: 96 mm stub sill. |
Texture | Not applicable. |
Ironmongery | Guidance for specification option: Insert requirements.
|
Accessories | Not required. AW629. Guidance for specification option: Reverse rebate adaptor, for 58 mm frame. AW712. Guidance for specification option: Bay pole, for 58 mm frame. AW715. Guidance for specification option: 100–120° bay pole, for 70 mm frame. AW716. Guidance for specification option: 120–140° bay pole, for 70 mm frame. |
Panel weight | Not applicable. Manufacturer guidanceRecommended weight limits (maximum). |
Size: | 2400 x 2400 mm. Guidance for specification option: Casement fixed light. As drawing. Guidance for specification option: Insert reference. As schedule. Guidance for specification option: Insert reference. Manufacturer guidanceRecommended size limits (maximum). |
Country of product manufacture | United Kingdom |
AluK 58BW Open In HI Thermally Broken Window System
AluK 58BW SA Open In Thermally Broken Student Accommodation Window System
AluK 58BW ST HI Open Out Thermally Broken Heritage Window System
AluK 77IS Concealed Open In Thermally Broken Commercial Window System
AluK 77IW Open In Window System
AluK 77IWE Open Out Window System
AluK C70S Open In Thermally Broken Window System
AluK C70S Open Out Thermally Broken Window System