Single Leaf: Anodized.

AluK (GB) Ltd Variant:

Aluminium residential hinged flush door system.

Jump to:
+44 (0)1291 639739 Website

Application

Suitable for use with residential new build and refurbishment projects, ideal for light and medium traffic environments.

Description

Aluminium residential hinged flush door system.


Features and benefits:

  • Doors are Secured by Design accredited and are Q-Marked in accordance with PAS 24.
  • Aluminium profiles are extruded in accordance with BS EN 12020, and are manufactured from grade 6060/6063 T6 aluminium.
  • Compliant with ADL1/ ADL2 capable of achieving U-values of 1.4 W/m²K.
  • A variety of powder coated colours are available in accordance with BS 6496 and BS EN 12206-1:2004.
  • Powder coating is applied to a Qualicoat standard, utilizing an inline flash anodizing pre-treatment process, with the polyester powder coating applied within 30 minutes of the flash anodizing process to ensure suitable adhesion.
  • Doors can be dual coloured, textured or have an anodized finish.


General information

Color

Other

Guidance for specification option:

Insert RAL colour requirement or type 'Not applicable' for anodized.

Finish

Anodized

Guidance for specification option:

To a minimum 15 micrometres thickness.

Powder-coated

Guidance for specification option:

Polyester powder coated to a minimum 60 micrometres thickness (with marine environment guarantee where applicable).

Material

Aluminium

Glass

Shape

Rectangle

Width

1000 mm

Guidance for specification option:

Single leaf: Hardware limits.

1200 mm

Guidance for specification option:

Single leaf: Hardware limits.

2000 mm

Guidance for specification option:

Double leaf: Tested limits.

2400 mm

Guidance for specification option:

Double leaf: Hardware limits.

Manufacturer guidance

Recommended size limits (maximum).

Height

2200 mm

Guidance for specification option:

Single leaf: Hardware limits.

Double leaf: Tested limits.


2400 mm

Guidance for specification option:

Single leaf: Hardware limits.

Double leaf: Hardware limits.

Manufacturer guidance

Recommended size limits (maximum).

Uniclass

Pr_30_59_24_02 Aluminium doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Product range

Residential Doors

Specification data - Aluminium doorsets

Configuration

Single, open in.

Guidance for specification option:

Fully rebated.

Single, open out.

Guidance for specification option:

Fully rebated.

Doorset size

1200 x 2400 mm.

Guidance for specification option:

Maximum size: Hardware limits.

1000 x 2200 mm.

Guidance for specification option:

Maximum size: Hardware limits.

As drawing.

Guidance for specification option:

Insert reference.

As schedule.

Guidance for specification option:

Insert reference.

Performance

-

Thermal

1.4 W/m²K.

Intruder resistance

-

Minimum requirement

Secured by Design certification and PAS 24.

Frame

-

Material

Aluminium.

Finish

-

Coating

Anodized.

Guidance for specification option:

To a minimum 15 micrometres thickness.

Texture

Not applicable.

Guidance for specification option:

For anodized.

Colour

Anodized.

Door leaf

-

Material

Aluminium.

Glazing

-

Type

Glass panels.

Guidance for specification option:

24–40 mm glass look-a-like panels, insert requirements.


Glass look-a-like panels incorporating two panes of minimum 6 mm-thick glass, with a 16 mm argon gas filled cavity and ceramic painted internal face with foil backed insulation to achieve a maximum 0.35 W/m²K centre pane. Exposed internal faces of insulation incorporate an internal polyester powder coated aluminium tray backing.

Glazing.

Guidance for specification option:

24–40 mm insulating glass units, insert requirements.


Insulating glass units incorporating a clear low emissivity inner pane and a clear outer pane with an argon gas filled cavity and 'warm edge' spacer bar to achieve a maximum centre pane U-value of 1.0 W/m²K. All glass within 800 mm from FFL should be toughened or laminated (within 1500 mm from FFL if within 300 mm of a door).

Infill panels.

Guidance for specification option:

24–40 mm insulating glass units, insert requirements.


Insulated sandwich panels incorporating two sheets of a minimum 2 mm-thick polyester powder coated aluminium sheet to match framing and minimum 24 mm non-combustible foam insulation core.

Beading

-

Type

Chamfered.

Square.

Material

Aluminium.

Finish

-

Coating

Anodized.

Guidance for specification option:

To a minimum 15 micrometres thickness.

Texture

Not applicable.

External colour

Anodized.

Internal colour

Anodized.

Film thickness (minimum)

15 micrometres.

Accessories

Not required.

AW712.

Guidance for specification option:

Bay pole, for 58 mm frame.

AW715.

Guidance for specification option:

100–120° bay pole, for 70 mm frame.

AW716.

Guidance for specification option:

120–140° bay pole, for 70 mm frame.

AW717.

Guidance for specification option:

140–160° bay pole, for 70 mm frame.

AW718.

Guidance for specification option:

160–180° bay pole, for 70 mm frame.

AW720.

Guidance for specification option:

Integral corner post, for 70 mm frame.

AW721.

Guidance for specification option:

Integral corner post, for 58 mm frame.

AW722.

Guidance for specification option:

Bay pole, for 70 mm frame.

AW724.

Guidance for specification option:

20 mm frame extender, for 70 mm frame.

AW725.

Guidance for specification option:

20 mm frame extender, for 58 mm frame.

AW728.

Guidance for specification option:

40 mm frame extender, for 70 mm frame.

Fanlight.

Guidance for specification option:

Insert requirements.

Laybar.

Guidance for specification option:

Insert requirements.

Letterplate.

Guidance for specification option:

Insert requirements.

Midrail.

Guidance for specification option:

Insert requirements.

Sidelight.

Guidance for specification option:

Insert requirements.

Execution

Installing hardware.

Outer frame

AW600.

Guidance for specification option:

70 mm slim chamfered frame.

AW601.

Guidance for specification option:

70 mm standard chamfered frame.

AW602.

Guidance for specification option:

70 mm standard ovolo frame.

AW603.

Guidance for specification option:

58 mm odd leg frame.

AW604.

Guidance for specification option:

58 mm standard frame.

Show more

Vent

AD400.

Guidance for specification option:

Open in.

AD401.

Guidance for specification option:

Open out.

Coupler

Not required.

AW702.

Guidance for specification option:

15 mm coupler, for 70 mm frame.

AW703.

Guidance for specification option:

15 mm coupler, for 58 mm frame.

AW705.

Guidance for specification option:

26 mm coupler, for 70 mm frame.

AW706.

Guidance for specification option:

26 mm coupler, for 58 mm frame.

Show more

Sub sill

Not required.

AW542.

Guidance for specification option:

150 mm sill

AW543.

Guidance for specification option:

177 mm sill.

AW544.

Guidance for specification option:

190 mm sill.

AW570.

Guidance for specification option:

96 mm stub sill.

Show more

Ironmongery

Guidance for specification option:

Insert requirements.

Panel weight

100 kg.

Guidance for specification option:

Two hinges per door.

125 kg.

Guidance for specification option:

Three hinges per door.

150 kg.

Guidance for specification option:

Four hinges per door.

Manufacturer guidance

Recommended weight limits (maximum).

Air permeability

Class 2 (300 Pa).

Watertightness

Class 9A (600 Pa).

Wind resistance

A3 (1200 Pa).