  • Movable wall system with full range of certified acoustic and fire performance. 
  • Can achieve a wide range of configurations with different panel types including pass doors and glazed panels. 
  • Manual and semi-automatic systems.
  • Independently certified production and quality management systems.

General information
Color

Customisable. Standard ranges availble.

Features

Movable wall system with full range of certified acoustic and fire peformance. Can achive a wide range of configurations with different panel types including passdoors and glazed panels. Manual and semi-automatic systems. Independantly certified production and qauality management systems.

Finish

Standard range of low pressure melamine (LPL) and high pressure lamite (HPL) available together with a limited range of anti fingerprint and anti bacterial finishes

Material

Tracks - Aluminium or steel dependant on panels weights. Panels - Aluminium and steel frames clad with high density particleboard with acoustic insulation to suit varrying degrees of acoustic perfirmance. Panels can be supplied with glazed panels or full height double glazed.

Shape

Rectangle

Size

Type 100 - thickness 113mm (39 - 54 dB Rw), type 100K - thickness 113mm (39 - 54 dB Rw), type 100K 57 dB Rw - thickness 119mm. Panel widths 650mm - 1350mm. Panel heights 7000mm nom.

WarrantyDescription

Standard - 2 years parts and labour. Extended warranties can be provided as part of a service contract with our authorised distributor network.

Uniclass 2015
Pr_25_71_57_80 Sliding stacking panel partitionsPrimary
Specification data - Sliding stacking panel partitions Enhanced data
Third party accreditation

DIN-EN-ISO-9001

DIN-EN-20-140-3

Independently verified (Finishes and Interiors Sector - FIS) acoustic test certification

EN-13501-2

Fire protection certification

Performance

Acoustic rating 39 dB Rw

35 Kg/m²

Acoustic rating 42 dB Rw

36 Kg/m²

Acoustic rating 45 dB Rw

50 Kg/m²  'MoVista' Full height double glazed

Acoustic rating 46 dB Rw

37 Kg/m²

Acoustic rating 47 dB Rw

52 Kg/m²  'MoVista' Full height double glazed

Acoustic rating 48 dB Rw

40 Kg/m²

Acoustic rating 49 dB Rw

43 Kg/m²

Acoustic rating 51 dB Rw

50 Kg/m²

Acoustic rating 53 dB Rw

55 Kg/m²

Acoustic rating 54 dB Rw

55 Kg/m²

Acoustic rating 57 dB Rw

65 Kg/m²

30 Minute FR (EN-13501-2) 46dB Rw

40 Kg/m² Refer to manufacturer for width/height limits

60 Minute FR (EN-13501-2) 46dB Rw

43 Kg/m² Refer to manufacturer for width/height limits

Operation

'ESS 'MoVista' Semi-automatic full height double glazed

Panels moved manually, seals operated automatically

Type 100 (concealed trim) Full manual

Panels moved manually, seals operated manually

Type 100K (exposed trim) Full manual

Panels moved manually, seals operated manually

Type 100KESS (exposed trim) Semi-automatic

Panels moved manually, seals operated automatically

Type100ESS (concealed trim) Semi-automatic

Panels moved manually, seals operated automatically

Seal pressure

Manually operated seal - 500N/Lm

Semi-autoamatic operated seal - 1500n/Lm

Dimensions (nominal) -
Structural opening size

Project Specific

Panel (average) -
Width

Equal size panels to suit opening width subject to panel arrangement (pass doors/junction panels).

Height

To suit floor to head track height subject to standard floor level variations (+/- 10mm). Higher floor height variations and head track deflection can be accommodated - please contact Hufcor for further details.

Thickness

To suit panel finish required and/or acoustic rating specified above.

Average panel weight -
Standard panel

35kg/m2 to 65kg/m2 nom subject to acoustic performance

Telescopic panel

40kg/m2 to 70kg/m2 nom subject to acoustic performance

Parking loads

Refer to manufacturers drawings for specific panel loads when stacked into parking areas.

Track system -
Head track

Type 38 aluminium single point track

Suitable for panel weights up to 180kg (loose fit ceiling trims).

Type 40 aluminium single point track

Suitable for panel weights up to 400kg

Type 34 aluminium double point track

Suitable for panel weights up to 450kg

Type 57 aluminium double point track

Suitable for panel weights up to 680kg

Type 11L steel double point track

Suitable for panel weights up to 635kg

Type 11 steel double point track

Suitable for panel weights up to 1360kg

Ceiling flange finish

Aluminium, RAL 9010

Aluminium, satin anodised

Special, RAL colour

Park position

Single point suspension

Double point suspension

Wall jamb and abutments

  • Type 100/100K standard 'female' profile wall jamb 80mm deep nom together with standard telescopic wall jamb 16mm/19mm deep.
  • Type 100/100K ESS standard 'female' profile wall jamb 120mm deep nom (to accommodate abutment mounted keyswitch) together with standard telescopic wall jamb 16mm/19mm deep.

Panels -
Construction

Aluminium and steel frame (subject to panel size), clad with high density particle board with acoustic insulation to suit acoustic performance

Finish as delivered

House collection low pressure laminate (LPL)

House collection high pressure laminate (HPL)

House collection anti-fingerprint high pressure laminate (CPL)

House collection high gloss writable high pressure laminate

House collection high gloss writable/magnetic high pressure laminate

Real wood

Specify timber species as veneer

Stretched fabric

Fabric manufacturer, Range and colour reference required

Sound absorption boards

LPL OR, HPL OR, Veneer panel finish

Full height double glazed

MoVista

Joints -
Detail

Aluminium with interlocking seal sections and magnetic seal strips subject to acoustic rating

Finish

  • Type 100K - exposed aluminium edge trim to provide shadow gap detail between panel joints
  • Type 100 - concealed aluminium edge trim to provide panel edge protection

Pass doors

Single inset pass door, nom size 900mm wide x 2100mm high

Subject to panel height

Double inset passdoor, nom size 1800mm wide x 2100mm high

Subject to panel height

Fixed full height end pivot door, 900mm wide nom

Hardware

Standard lever handle on square backplate with standard lock

Standard lever handle on square backplate with emergency escape function lock

Emergency exit push bar

Junctions and corners

Standard solid junction panels to suit panel arrangement

Glass manifestation

Plain clear glass

Opaque film manifestation

Applied on site by others

'Switchable' smart glass

Requires semi automatic panel operation

Accessories

Magnetic contact switch to telescopic panel wall abutment

For example - lighting control

Vision panel to pass door

Size Required

Alternative deep bottom seals to accommodate excessive head track deflection or uneven floor levels

Refer to Hufcor for seal depth selection

Execution