NBS Source
I'm a manufacturer
Compare variants

PVC Vents

Verified by manufacturer 6 months ago

PVC Vents 160 mm

Wallbarn Ltd Variant:

Welded PVC aerators for to fit onto concrete slab for single ply membranes.

Jump to:
+44 (0)20 8916 2222 Website

Application

Welded PVC aerators to fit onto concrete slab for single ply membranes.

Description

Tough and durable vent, designed to help aerate concrete slabs and allow the structure to breathe.


Features and benefits:

  • It draws moisture away from a concrete slab and is placed onto the bare concrete beneath the waterproofing membrane and insulation.
  • Bonded by using hot air gun (not direct contact to a flame).
  • The membrane is welded to the top of the base of the vent, creating a flue which helps to draw vapour out of the concrete.
  • There are a series of ribs along the underside of the round base plate which encourage the movement of vapour along the base and into the flue and also act to alleviate any hot air which might appear between the slab and the membrane.
  • The top of the flue has three lateral holes to allow the vapour to escape into the atmosphere.
  • It is covered by a hood which overlaps the internal holes, preventing rainwater entering the system but still allowing the passage of vapour.

General information

Color

Black

White

Material

Polyvinyl chloride (PVC)

TPE (Thermoplastic Elastomer)

Uniclass

Pr_30_59_29_30 Flat roof ventilatorsPrimary

CAWS

J41/485 Roof ventilators

J41/80 Roof ventilators

J42/490 Roof ventilators

Product range

Roof Drainage Outlets

Specification data - Flat roof ventilators

Material

PVC/ TPE.

Manufacturer guidance

  • TPE - (Thermoplastic Elastomer), a compound of EPDM and polypropylene (caps).
  • PVC - Polyvinyl chloride (Aerators).

Colour

Black/ white.

Size

-

Diameter or section (minimum)

125 mm.

Flange base (minimum)

390 mm.

Product Reference

PVC Vents

Height

160 mm.

Manufacturer guidance

The shorter, broader vent can be used for deck areas where a shorter pipe is required. The extra-long vent pipe may be required for areas where some sort of covering is placed onto the deck and the hood needs to be exposed.

Hood

Manufacturer's standard.

Guidance for specification option:

Black round cap.

ESTRAER®.

Guidance for specification option:

Two conical funnels.

Manufacturer guidance

The ESTRAER® funnel shaped hood comprises two conical funnels which join up at a central hole at the top of pipe. It creates extra suction on the pipe, helping to draw out a greater amount of vapour and air from the concrete. For use where the concrete deck and insulation needs to be aerated and ventilated.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Similar products from Wallbarn Ltd

TPE Vents