NBS Source
PS Hi Flow Grout Mortar

Application

Designed for anchor or baseplate grouting in locations such as:


  • Under machinery and stanchion plates.
  • Grouting rails and bridge bearings.
  • Fixing bolts.
  • Parapet rails.


Should be mixed using water that complies with BS EN 1008 (as for concrete) – consult manufacturer for information.

Description

High fluidity grouting mortar, composed of low alkali, Portland cements and other cementitious binders, combined with high purity aggregates and compatible admixtures.


Features and benefits:

  • Will not bleed or shrink.
  • High strength.
  • Chloride-free.
  • Will compensate for shrinkage in both plastic and hardened states.
  • Can be used for grouting sections up to 100 mm thick.
  • Contains less than 3 kg/m³ of sodium oxide.
  • Can be mixed using an electric or pneumatic power tool.
  • Complies with Highway Spec 2601 for bedding mortars.
  • Yield of mixed grout (per tonne of dry powder): 0.61 m³.
  • 500 mm flow channel.

General information

Shape

Formless

Material

Cement

Low alkali, Portland cements and other cementitious binders, combined with high purity aggregates and compatible admixtures.

Uniclass 2015

Pr_20_31_53_52 Metal anchor and fixings groutsPrimary

CAWS

G10/443 Proprietary filling/ bedding of column bases

Specification data - Metal anchor and fixings grouts Enhanced data

Standard

To BS EN 1008.

Grout type

Cement based.

Identity requirements

Water.

To BS EN 1008.

Compressive strength - 1 day

15 N/mm².

Compressive strength - 7 days

45 N/mm².

Compressive strength - 28 days

60 N/mm².

Expansion

0.00%.

After 1-3 days.

Setting time

Approximately.

4 hours, 6 hours.

After initial coat / After final coat.

Accessories/ Other requirements

Not required.

PUDLO CWP.

Surestop BWB.

Surestop SM.