Pro-Cut 3-Sided Builder's Work Opening (British Gypsum)

Verifisert av produsent for 1 måned siden

British Gypsum 50DC60

Drywall Pro-cut Ltd Variant:

Three sided, flat-packed component designed to form an opening within British Gypsum single-frame metal stud partitions.

Gå til:
01827 213201 Nettside

Applikasjon

  • Designed to form an opening within British Gypsum single-frame metal stud partitions.
  • All materials and fixings are installed off site in a quality-controlled environment and delivered safely to site.
  • See project-specific British Gypsum detailing for specified partitioning systems for guidelines on site installation.

Beskrivelse

Three sided, flat-packed component designed to form an opening within British Gypsum single-frame metal stud partitions enabling penetration of services through the partition to reach adjoining spaces. Accommodates a range of bespoke opening sizes with allowance for building deflection to form a specified opening flush to the underside of the soffit.


Fabricated in an offsite environment to maximize safety and ensure high levels of quality and compliance with associated regulatory requirements and manufacturer warranties. Complies with all thermal and acoustic requirements as a critical component of the extensive range of British Gypsum partitioning systems whilst providing high levels of protection against fire for periods of up to 120 minutes in standard applications.


Features and benefits:

  • Full penetration design using third-party fire stopping material should also reference BS EN 1366-3 to properly assess penetration fire resistance properties in addition to any basic test data provided by British Gypsum to BS EN 1364-1.
  • Metal sections all meet BS EN14195:2014 requirements for metal framing components for gypsum board systems.
  • Installation in accordance with British Gypsum recommendations using appropriate third-party BS EN 1366-3 compliant fire stopping material should achieve full fire rating performance for any specified British Gypsum partitioning system.
  • Fire testing of full partitioning systems containing this product or equivalent conducted according to BS EN1364-1:1999.
  • Gypframe metal channels are 100% recyclable (European Waste Catalogue code is 12 01 01).
  • Gypsum based components can be fully recycled provided they are not contaminated by non-gypsum materials.
  • Component complies with British Gypsum SpecSure® warranty verifying that approved partitioning systems will perform as specified upon installation and will continue to do so throughout the design life of the building.

Generell informasjon

Farge

Silver

White

Materiale

Metal

Gypsum

Plasterboard

Form

Other

Lengde

Bespoke

Veiledning for spesifikasjonsvalg:

As specified.

Bredde

50 mm

62 mm

72 mm

94 mm

148 mm

Høyde

50 mm

70 mm

Garanti­beskrivelse

Other

Veiledning for spesifikasjonsvalg:

Component complies with British Gypsum SpecSure® warranty verifying that approved partitioning systems will perform as specified upon installation and will continue to do so throughout the design life of the building.

Uniclass

Ss_25_10_30_35 Skilleveggsystemer av gipsplaterPrimær

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

SKU Code

50DC60, 62DC60, 72DC60, 94DC60, 148DC60, 50EDC70, 72EDC80, 94EDC70, 148EDC80

Spesifikasjonsdata - Skilleveggsystemer av gipsplater

Klassifiseringsdata

Framing

British Gypsum 50DC60.

Veiledning fra produsent

Metal Track Selections.

Resilient layer

Not required.
Resilient bar one side.
Resilient bar two sides.

Linings

British Gypsum 12.5 mm Wallboard one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 7.7 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Wallboard one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 9.5 kg/m².
  • No. of layers: 1.

British Gypsum 12.5 mm Soundbloc one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 10.3 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Soundbloc one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 13.0 kg/m².
  • No. of layers: 1.

British Gypsum 12.5 mm Fireline one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mK.
  • Minimum weight: 9.7 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Fireline one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mK.
  • Minimum weight: 11.4 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Duraline one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 14.1 kg/m².
  • No. of layers: 1.

British Gypsum 12.5 mm Moisture Resistant one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 8.3 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Moisture Resistant one layer.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 9.8 kg/m².
  • No. of layers: 1.

British Gypsum 12.5 mm Wallboard two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 7.7 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Wallboard two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 9.5 kg/m².
  • No. of layers: 2.

British Gypsum 12.5 mm Soundbloc two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 10.3 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Soundbloc two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 13.0 kg/m².
  • No. of layers: 2.

British Gypsum 12.5 mm Fireline two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mK.
  • Minimum weight: 9.7 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Fireline two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mK.
  • Minimum weight: 11.4 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Duraline two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.25 W/mK.
  • Minimum weight: 14.1 kg/m².
  • No. of layers: 2.

British Gypsum 12.5 mm Moisture Resistant two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 8.3 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Moisture Resistant two layers.

Veiledning for spesifikasjonsvalg:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.19 W/mK.
  • Minimum weight: 9.8 kg/m².
  • No. of layers: 2.

Fasteners

British Gypsum compliant fixings.

Veiledning for spesifikasjonsvalg:

Suitable fixings are always selected by Drywall Pro-Cut for compliance with British Gypsum performance requirements.

Joint treatment

Veiledning for spesifikasjonsvalg:

Consult manufacturer and insert requirements or omit.

Finish

Veiledning for spesifikasjonsvalg:

Consult manufacturer and insert requirements or omit.

System accessories

Veiledning for spesifikasjonsvalg:

Consult manufacturer and insert requirements or omit.

Length

As specified.

Veiledning for spesifikasjonsvalg:

Consult manufacturer and insert requirements.

Veiledning fra produsent

Metal Track.

Width

50 mm.

Veiledning fra produsent

Metal Track.

FlangeDepth

50 mm.

Veiledning fra produsent

Metal Track.

Gauge

0.60 mm.

Veiledning fra produsent

Metal Track.

Gauge thickness.

Unit weight

0.70 kg/Lm.

Veiledning fra produsent

Metal Track.

Metal unit weight.

Deflection

15 mm downward.
25 mm upward/ downward.
50 mm downward.

Stud centres

400 mm.
600 mm.
1200 mm.

Form

Modular.
Adjustable.

Opening size

Veiledning for spesifikasjonsvalg:

Consult manufacturer and insert requirements.

Adjustable:

  • Opening Height (mm)  Min: 100 Max: 600.
  • Opening Width (mm)  Min: 100 Max: 1200.

Modular:

  • Opening Height (mm) Min: 250 Max: 600.

Bærekraftsdata

Resirkulerbarhet

Veiledning for spesifikasjonsvalg:

  • Gypframe metal channels are 100% recyclable (European Waste Catalogue code is 12 01 01).
  • Gypsum based components can be fully recycled provided they are not contaminated by non-gypsum materials.

Dokumentasjon

Pro-Cut 3-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Builder's Work Opening (British Gypsum)

Lignende produkter fra Drywall Pro-cut Ltd

Pro-Cut 3-Sided Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut Deflection Head (British Gypsum)

Pro-Cut Deflection Head (British Gypsum)

Pro-Cut Deflection Head (Siniat)

Pro-Cut Deflection Head (Siniat)