NBS Source
Jeg er en produsent
Dette produktet har nylig blitt oppdatert og dette er den nyeste versjonen.

Applikasjon

Sliding, stacking and folding acoustic wall designed to limit noise transmission between rooms.

Beskrivelse

Sliding stacking panel partition.


Features and benefits:

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, able to deal with uneven floor levels.
  • Manual, semi-electric or fully electric options.
  • No floor track.
  • Faceted layouts, corner panels, junction panels, glazing cutouts, pass door options available.

Generell informasjon

Farge

-

Produsentveiledning

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Overflatebehandling

-

Produsentveiledning

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Materiale

Aluminium

Glass

Form

Rectangle

Lengde

Bespoke

Produsentveiledning

1200mm wide x 20000mm high maximum panel dimension

Bredde

Bespoke

Produsentveiledning

1200mm wide x 20000mm high maximum panel dimension

Garanti­beskrivelse

Two year

Uniclass

Pr_25_71_57_80 Skyvbare foldeveggerPrimær

CAWS

L20/545 Sliding stacking panel partitions

SKU Code

100

Spesifikasjonsdata - Skyve- og stabelbare skillevegger med paneler

Klassifiseringsdata

Performance

Rw 37 dB, in accordance with BS EN ISO 140-3.
Rw 41 dB, in accordance with BS EN ISO 140-3.
Rw 43 dB, in accordance with BS EN ISO 140-3.
Rw 44 dB, in accordance with BS EN ISO 140-3.
Rw 45 dB, in accordance with BS EN ISO 140-3.
Rw 46 dB, in accordance with BS EN ISO 140-3.
Rw 47 dB, in accordance with BS EN ISO 140-3.
Rw 48 dB, in accordance with BS EN ISO 140-3.
Rw 50 dB, in accordance with BS EN ISO 140-3.
Rw 51 dB, in accordance with BS EN ISO 140-3.
Rw 52 dB, in accordance with BS EN ISO 140-3.
Rw 53 dB, in accordance with BS EN ISO 140-3.
Rw 55 dB, in accordance with BS EN ISO 140-3.
Rw 57 dB, in accordance with BS EN ISO 140-3.
Rw 58 dB, in accordance with BS EN ISO 140-3.

Veiledning for spesifikasjonsvalg:

Please note the Type TL 1 'E' track single point suspension is not suitable for this rating.

Rw 60 dB, in accordance with BS EN ISO 140-3.

Veiledning for spesifikasjonsvalg:

Please note the Type TL 1 'E' track single point suspension is not suitable for this rating.

Veiledning fra produsent

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 100 panels have been tested to achieve sound reduction ratings of up to Rw 60 dB, measured in accordance with EN ISO 140-3.
  • Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to control room sound absorption levels using optional fabric wrapped acoustic panels or optional perforated/ slotted sound absorbent boards.

Operation

E: Fully electric.

Veiledning for spesifikasjonsvalg:

  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electric relocation of panels by motors within trolleys, housed within special track type.
  • Each panel requires two-point suspension.
  • Power to trolleys conducted via busbars within track.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


M: Manual.

Veiledning for spesifikasjonsvalg:

  • Manual relocation of panels.
  • Seals operated by removable winding handle.


SE: Semi-electric.

Veiledning for spesifikasjonsvalg:

  • Manual relocation of panels.
  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electrical supply to panels conducted through contacts in panel edge profiles.
  • Remote master switching (to be within sight of TE panel, for safe operation.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


Dimensions (nominal)

-

Panel (average)

-

Width

Veiledning for spesifikasjonsvalg:

Up to 1230 mm (maximum). Wider panels possible to special order; insert requirements.

Height

Veiledning for spesifikasjonsvalg:

Minimum: 1.5 m up to 15 m *maximum); insert requirements.

Thickness

19 mm.

Track system

-

Wall jamb and abutments

Finished to match panels as standard.

Veiledning fra produsent

  • Can be supplied without wall jambs in special cases.
  • Independent wall jamb available in instances where wall structure unsuitable for standard wall jamb.
  • Fixed to structural floor and soffit.

Panels

-

Construction

Internal bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard.

Finish as delivered

Back painted glass.
Client supplied fully finished boards.

Veiledning for spesifikasjonsvalg:

Insert details as required.

Factory spray paint to RAL colour.

Veiledning for spesifikasjonsvalg:

Insert requirement.

High pressure laminate.
Lacquered steel sheet to RAL colour.

Veiledning for spesifikasjonsvalg:

Insert requirement.

Magnetic back painted glass.
Magnetic whiteboard laminate.
Perforated sound absorbent board.

Veiledning for spesifikasjonsvalg:

Perforation specification by specifier; insert details as required.

Priming sheet ready for ‘on site’ decoration by others.

Veiledning for spesifikasjonsvalg:

Insert details as required.

Slotted sound absorbent board.

Veiledning for spesifikasjonsvalg:

Slot specification by specifier; insert details as required.

Standard laminate.
Stretch fabric system.

Veiledning for spesifikasjonsvalg:

Thickness and fabric specification by specifier; insert details as required.

Veneer.

Veiledning for spesifikasjonsvalg:

Insert details of species type and cut.

Whiteboard laminate.

Veiledning fra produsent

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

Paneltype

Veiledning for spesifikasjonsvalg:

Project specific, consult manufacturer and insert requirements.

Veiledning fra produsent

Panel type and number.

Track profile

-

Veiledning fra produsent

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters; consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.


Track layout

TL 1 ‘E’ system.

Veiledning for spesifikasjonsvalg:

  • Straight runs only, panels stacked within opening.
  • Single track, single point suspension.

TL 2 ‘Za’ system.

Veiledning for spesifikasjonsvalg:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Minimal panel stack.

TL 3 ‘Zb’ system.

Veiledning for spesifikasjonsvalg:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Panels stacked within opening to left or right of track.

TL 4 ‘K’ system.

Veiledning for spesifikasjonsvalg:

  • Panels stacked in recess cupboard.

TL 5 ‘K’ system.

Veiledning for spesifikasjonsvalg:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  •  Two point suspension.

TL 6 ‘K’ system.

Veiledning for spesifikasjonsvalg:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  • Stacked behind reveal, two point suspension.

TL 7 ‘K’ system.

Veiledning for spesifikasjonsvalg:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  •  Stacked inside wall recess, two point suspension.

TL 8 ‘K’ system.

Veiledning for spesifikasjonsvalg:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  • Stacked in branches to one or both sides.

Veiledning fra produsent

Please note: If Type TL1 'E' track is specified then Rw 58dB (laboratory tested) sound reduction and Rw 60dB (laboratory tested) sound reduction is not suitable.

Fire performance

To EN 13501-1, Class D.

Veiledning for spesifikasjonsvalg:

As standard.

Contact manufacturer for full classification details. The classifications depend on factory of manufacture and the corresponding finish.

To EN 13501-1, Class B.

Veiledning for spesifikasjonsvalg:

Contact manufacturer for full classification details. The classifications depend on factory of manufacture and the corresponding finish.

Veiledning fra produsent

  • Particular fire rating may not be available in all panel types and finishes; consult manufacturer prior to specification.
  • Available with optional fire separation construction.

FireRating

Not fire rated.

Veiledning for spesifikasjonsvalg:

Standard.

30 minute fire rated.
60 minute fire rated (no pass door).

Partition assembly

Refer to manufacturer drawing (SL – 101, SL – 102 and SL – 103), for disposition of specified elements.

Panel vertical edge type

Exposed satin-anodized aluminium.
Exposed powder-coated aluminium.
Concealed satin-anodized aluminium.
Concealed powder-coated aluminium.

Panel stacking arrangement

Bi–parting.
Double stack.
Single stack.

Ceiling angle trim

None.
Exposed 20 mm from underside of ceiling (TL1 'E' track only).

Veiledning for spesifikasjonsvalg:

Single point suspension only.

Flush with underside of ceiling.

Veiledning for spesifikasjonsvalg:

Two point suspension only.

Track finish

White.

Veiledning for spesifikasjonsvalg:

As standard, spray painted.

Plain RAL colour.

Veiledning for spesifikasjonsvalg:

Insert requirement.

Supporting structure

Veiledning for spesifikasjonsvalg:

Project specific, consult manufacturer and insert requirements.

Veiledning fra produsent

Type of structure supporting the weight of the folding wall above the head track.

Barriers in ceiling void

Required.
Not required.

Baffle

Required.
Not required.

Vision panels

Required.
Not required.
As drawing.

Bærekraftsdata

Inneholder Red List-materialer

No

Opprinnelsesland for materiale

-

Veiledning fra produsent

Germany, Holland or Sweden

Produksjonsland for produktet

-

Veiledning fra produsent

Germany, Holland or Sweden

Materiale

Aluminium
Glass

Resirkulerbarhet

Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production

Resirkulert innhold

17.5 %

Forventet liv

30 year

Dokumentasjon

Type 100 Product

Type 100 Product

Nyheter

Movawall Systems Ltd - Showroom

Movawall Systems Ltd - Showroom

Type 100 Fully Electric - London School of Hygiene

Type 100 Fully Electric - London School of Hygiene

Type 100 - Longwater Reading

Type 100 - Longwater Reading

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE - Radiation Protection

Type 100SE - Radiation Protection

Type G100 and Type 100SE Combination - Taunton School

Type G100 and Type 100SE Combination - Taunton School

Type 100 - Salesforce Tower

Type 100 - Salesforce Tower

Type 100 - Devonshires, Leeds

Type 100 - Devonshires, Leeds

Type 100SE - Financial Services Firm, London

Type 100SE - Financial Services Firm, London

Lignende produkter fra Movawall Systems Ltd

Type 80 movable acoustic wall

Type 80 movable acoustic wall

Type Float   - Gliding Wall Panels

Type Float - Gliding Wall Panels

Type G200 framed glass sliding partition

Type G200 framed glass sliding partition

Type GG / GG Plus glazed movable wall

Type GG / GG Plus glazed movable wall

Type RG Plus glazed acoustic movable wall

Type RG Plus glazed acoustic movable wall

Type Slide   - Sliding Wall Partitions

Type Slide - Sliding Wall Partitions