NBS Source
Jeg er en produsent
Sammenlign varianter

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud

Verifisert av produsent for 6 måneder siden

K10 127 2 x 12.5 mm Fire Board

Protektor Group UK Variant:

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Gå til:
01562 515200 Nettside

Applikasjon

  • Suitable for use where fire and acoustic performance is required.
  • Suitable for use in large commercial spaces.

Beskrivelse

Protektor 127 ‘C’ Stud Partition(s) – 50 mm Stud.

Features and benefits:

  • Severe duty rating to BS 5234.
  • Sound insulation (Rw dB): up to 53 dB Rw.
  • Available with or without acoustic partition roll.

Generell informasjon

Farge

Other

Overflatebehandling

Other

Materiale

Plasterboard

Metal

Form

Other

Lengde

Bespoke

Bredde

Bespoke

Høyde

Bespoke

Uniclass

Ss_25_10_30_35 Skilleveggsystemer av gipsplaterPrimær

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Spesifikasjonsdata - Skilleveggsystemer av gipsplater

Systemytelse

Sound insulation, Rw (minimum) to BS EN ISO 10140-2 or BS EN ISO 140-3

42 Rw (dB).

Fire resistance to BS EN 1364-1 and classification to BS EN 13501-2

EI 120.

Duty rating to BS 5234-2

Severe duty (SD).

Maximum height - cold state

3800 mm.

Thickness

102 mm.

Klassifiseringsdata

System manufacturer

Protektor Group UK Ltd.

Framing

Protektor ECO or MAXI TEC 50 mm C Stud; Protektor ‘ECO’ 52 mm Deep ‘U’ Channel; Protektor ‘ECO’ 52 mm U Track.

Veiledning for spesifikasjonsvalg:

Studs:

  • Protektor ECO or MAXI TEC 50 mm C Stud at 300 mm, 400 mm or 600 mm centres depending on heights.

Head detail:

  • Protektor ‘ECO’ 52 mm Deep ‘U’ Channel x 0.5 mm.

Base detail:

  • Protektor ‘ECO’ 52 mm U Track x 0.5 mm.

Track fixing:

  • Protektor ‘U’ Channels fixed at 400 mm centres into a suitable soffit unless stated otherwise.

Insulation

None.

Fire separation

-

Fire-stopping

-

Veiledning fra produsent

As required for penetrations and for base, head and any abutments to masonry, concrete or steelwork.

Insert requirements.

Linings

Two layers 12.5 mm fire board.

Fasteners

Protektor Drywall Screw’s at 300 mm centres (reduced to 200 mm at external edges).

Joint treatment

-

Veiledning fra produsent

All boards to be butt-jointed and either paper-taped or taped and jointed, or scrim taped and skimmed.

Insert requirements.

Finish

-

Veiledning fra produsent

Consult manufacturer and insert requirements.

Seamless finishes: using board manufactures finishing products as per their recommendations and Protektor UK products as clause 471 Protektor paper and corner tape or 680 Seamless finishings using Protektor corner, angle and stop bead.

System accessories

Not required.
Protektor ‘ECO’ 70 mm Bracing Strip x 0.6 mm.

Veiledning for spesifikasjonsvalg:

  • Fixing type: Protektor 13 mm Wafer Head Screws.
  • Protektor Flat plate to be installed at all horizontal board joints for fire rated partitions and below deflection heads.

Pattress.

Veiledning for spesifikasjonsvalg:

For plywood installation, Protektor service support plates can be used. These are suitable for either 12 mm, 15 mm or 18 mm.

Høyde

-

Veiledning fra produsent

Build heights.

Consult manufacturer and insert requirements.

  • 600 mm centres: 3400 mm.
  • 400 mm centres: 3600 mm.
  • 300 mm centres: 3800 mm.

Sealing (joints and penetrations)

Intumescent acoustic sealant.

Veiledning for spesifikasjonsvalg:

Twin beads of sealant 6 mm to 8 mm in diameter to base and head track to perimeter junctions with walls, floors, and ceilings and around openings. Use expanding intumescent mastic for all fire rated partitions to head and floor channels below head track and board fillets as required.

Deflection

-

Veiledning fra produsent

For up to 25 mm deflection, use board fillets to allow for a 5–10 mm overlap of vertical boarding against board fillets. Boards fillets should have 2 x 6 mm beads of mastic to the substrate, and 2 x beads of mastic to the head track. Please refer to manufacturer for anything above 25 mm.

Insert requirements or omit.

Standarder

To BS EN 1264-1, BS 476, BS 5234-2, BS EN ISO 140-3, BS EN 1364 and BS 7634.

Veiledning for spesifikasjonsvalg:

  • BS EN 1264-1 / BS476, Fire resistance tests for non-loadbearing elements - Walls.
  • BS 5234-2, Specification for performance requirements for strength and robustness including methods of test.
  • BS EN ISO 140-3, Acoustics - Measurement of sound insulation in buildings and of building elements. Laboratory measurement of airborne sound insulation of building elements.
  • BS EN 1364, Fire resistance tests for non-loadbearing elements.
  • BS 7634, Galvanised Steel Studs and Channels for Stud and Sheet Partitions.

Bærekraftsdata

Materiale

Plasterboard
Metal

Lignende produkter fra Protektor Group UK

Protektor 126 ‘C’ Stud Partition(s) – 50 mm Stud

Protektor 126 ‘C’ Stud Partition(s) – 50 mm Stud