Verifisert av produsent for 1 måned siden
Level 2
Low profile security rooflight for flat roofs with thermally decoupled liner. Certified Secured By Design by the LPCB.
Suitable for all nominally flat roof constructions in accordance with certified installation detail (Drawing Number PS_100INST).
The widest range of Secured by Design accredited rooflights that are tried and tested to give peace of mind that security building regulations are met.
Features and benefits:
Farge | Black Veiledning for spesifikasjonsvalg: RAL9005. Grey Veiledning for spesifikasjonsvalg: Light Grey (BS00A09), Dark Grey (BS00A13). White Veiledning for spesifikasjonsvalg: RAL9010. Other Veiledning for spesifikasjonsvalg: As per manufacturer and includes BS, RAL and other special colours to match roof covering available on request. |
Overflatebehandling | Powder-coated |
Materiale | Glass Stainless steel |
Form | Square Rectangle |
Garantibeskrivelse | One year Veiledning for spesifikasjonsvalg: On ancillary items. Five year Veiledning for spesifikasjonsvalg: On glass. Ten year Veiledning for spesifikasjonsvalg: On frames upon the rooflights being registered for free online via the manufacturer website. |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
SKU Code | Level 2, Level 3 |
Product range |
Klassifiseringsdata | |
Form | Flat. |
Size | Veiledning for spesifikasjonsvalg: Insert requirements:
|
Frame | |
Material | Stainless steel. |
Finish | |
Coating | Polyester powder coating. |
Colour | Black (RAL 9005). Dark Grey (BS 00A13). Light Grey (BS 00A09). White (RAL 9010). Any BS. Veiledning for spesifikasjonsvalg: Insert requirements. Any RAL. Veiledning for spesifikasjonsvalg: Insert requirements. Veiledning fra produsentFour standard Paint colours are available with matching glazing beading and Thermoliner®. |
Glazing or infill | |
Type | Insulating glass units. |
Construction | 6 mm Solar Low 'E' Toughened Outer, 12 mm Cavity, 18 mm TSG DCT18 (glass-poly-glass) Inner. Veiledning for spesifikasjonsvalg: SR2 glazing only. 6 mm Solar Low 'E' Toughened Outer, 12 mm Cavity, 20 mm TSG DCT20 (glass-poly-glass) Inner. Veiledning for spesifikasjonsvalg: SR3 glazing only. |
Integral kerb | Insulated. Veiledning for spesifikasjonsvalg: Insulated kerb to be formed on site as per certified installation details. |
Operation | |
Type | Fixed shut. |
Accessories | Not required. Coated stainless intruder security bars. |
Standard | To BS EN1279-2. |
Tredjepartssertifisering | Loss Prevention Standard: 1175 issue 7 Level 2 (without bars), Loss Prevention Standard: 1175 issue 7 Level 3 (with bars), KM 93754, BSI Kitemark and QA Certificate. |