Verifisert av produsent for 4 måneder siden
Trackless Bi-Folding Speed Gate - EAG50010
Designed for applications requiring dependable security and reliable operational performance, the trackless bi-folding speed gate is specified for use across utilities and distribution environments, as well as commercial, residential, and government sites including banks, embassies, warehouses, airports, schools, and universities, where automated bi-folding speed gates form part of the perimeter access control strategy.
The trackless bi-folding speed gate features an integrated drive mechanism that controls the smooth, rapid opening and closing of the bi-folding gate. The system synchronises both gate leaves to deliver controlled, reliable operation without the need for a bottom or top track. This trackless design eliminates height restrictions and removes the requirement for large road-mounted tracks, providing an efficient access control solution.
Features and benefits:
Farge | Other ProdusentveiledningProducts can be powder-coated to any RAL or BS reference. |
Overflatebehandling | Powder-coated ProdusentveiledningStandard finish for mild steel fabrication:
|
Materiale | Steel |
Form | Rectangle Square |
Bredde | Bespoke ProdusentveiledningGuidance for specification option:
Note: Maximum width may be subject to limitation for some infill options due to weight, combination with height, or wind loadings. Please contact manufacturer for further guidance. |
Høyde | Bespoke ProdusentveiledningTypically, the height of the gate is 2400 mm or 3000 mm but can be designed to bespoke requirements with the manufacturer's in house design team. |
Garantibeskrivelse | One year |
Uniclass | |
CAWS | Q50/20 Gate Q50/15 Steel gate Q40/560 Steel gates and posts Q40/45 Proprietary gates Q40/570 Proprietary gates and posts Q50/130 Gate Q50/120 Steel gate Q41/190 Vehicle access point barriers |
SKU Code | EAG50010 |
Klassifiseringsdata | |
Product reference | Bi-folding Trackless Speed Gate. |
Performance characteristics | |
Other | Complies with gate safety standard BS EN 13241-1. |
Dimensions | |
Span | 5000 mm. Veiledning for spesifikasjonsvalg: Single leaf - maximum. 10 000 mm. Veiledning for spesifikasjonsvalg: Double leaf - maximum. Bespoke. Veiledning for spesifikasjonsvalg: Consult manufacturer and insert requirements. Veiledning fra produsentConsult manufacturer and insert requirements.
Note: Maximum width may be subject to limitation for some infill options due to weight, combination with height, or wind loadings. |
Height | 2400 mm. 3000 mm. Bespoke. Veiledning for spesifikasjonsvalg: Consult manufacturer and insert requirements. Veiledning fra produsentTypically, the height of the gate is 2400 mm or 3000 mm but can be designed to bespoke requirements with the manufacturer's in house design team. |
Posts | Rectangular hollow section (RHS) 400 x 200 mm. |
Gate leaves | Carbon steel. |
Hardware | |
Hinges | Heavy duty included. Thrust and needle bearings with grease points. |
Securing | Hydraulically locked in closed position. |
Operating | Automatic – PLC controlled hydraulic system. |
Finish as delivered | |
Worked finish | Blast cleaned, SA 2.5. |
Applied finish | Interpon D1036 polyester powder-coated (PPC) (or equivalent). |
Drive/ Control | 100% duty cycle rated. 240 V 16 A supply. Veiledning for spesifikasjonsvalg:
|
Access control | Automatic Number Plate Recognition (ANPR). Card reader. Digital keypad. Radio control system. Push button control. |
Gate infill | Not required. Acoustic solid. Bar. Bar and weldmesh. Ornate. Palisade. Perforated steel sheet. Weldmesh. Special order. |
Top protection | Not required. Serrated edge (up to 100 mm). Barbed tape. Barbed wire (flat wrap). Palisade struts. Rotating spikes. |
Format | Bi-folding. |
Method of operation | Powered operation. Veiledning for spesifikasjonsvalg:
|
Colour | Veiledning fra produsentProducts can be powder-coated to any RAL or BS reference. Insert requirements. |
Accessories | None. Signage. Traffic lights. Light curtain. |
Safety | Designed to DHF TS 013. Induction loop amp. CAT3 safety edges. Dual height photocells. Laser scanner (optional). Light curtain (optional). Traffic lights (recommended). |
Electrical supply | Requires 240 V; 16 A. |
Foundation layout | Manufacturer's standard. Veiledning for spesifikasjonsvalg: Consult manufacturer for details. |
Inneholder Red List-materialer | No |
Produksjonsland for produktet | United Kingdom |
Plassering av produksjonsanlegg | |
Materiale | Steel |
Forventet liv | 15 year |