Miami Dade Testing. evguard® laminating interlayer and evguard® MPE multi-layer polyester. Testing of Large Missile Impacts, and Positive and Negative Cyclic Loads TAS 201-94 and TAS 203-94 and FBC 2010 IMPACTS: The samples were impacted in accordance with TAS 201-94 and FBC 2010. The samples did not fail. CYCLIC WIND LOADS: The samples were subjected to cyclic wind loads in accordance with TAS 203-94 and FBC 2010. The samples successfully completed the cyclic wind loads to verify a Design Load of +90.00 PSF/-90.00 PSF and for R&D purposes they were cycled successfully at +/-120 PSF were no tearing of interlayer was viewed or any frame pull outs were observed. The "Fixed Window" product was tested in accordance with and meets the requirements to comply with Florida Building Code 2010.
Contact Folienwerk Wolfen GmbH by clicking the button below to find out which products were used in this Other.
ISO 9001
ISO 50001 Folienwerk Wolfen
DIBt General Building Authority Approval
BRE Certification Folienwerk Wolfen