Movawall Systems Ltd

Top hung movable acoustic wall.

Siirry kohtaan:
+44 (0)20 8391 8790 Verkkosivu

Käyttötarkoitus

Sliding, stacking and folding acoustic wall designed to limit noise transmission between rooms.

Kuvaus

Sliding stacking panel partition.


Features and benefits:

  • Individually operated, top hung panels, purpose made to suit any opening size.
  • Retractable top and bottom seals, able to deal with uneven floor levels.
  • Manual, semi-electric or fully electric options.
  • No floor track.
  • Faceted layouts, corner panels, junction panels, glazing cutouts, pass door options available.

Yleistiedot

Väri

-

Valmistajan ohjeistus

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Viimeistely

-

Valmistajan ohjeistus

Standard Laminate, factory spray painted, fabric wrapped panels, high pressure laminate, veneer, white board, magnetic white board or to clients requirements

Materiaali

Aluminium

Glass

Muoto

Rectangle

Pituus

Bespoke

Valmistajan ohjeistus

1200mm wide x 20000mm high maximum panel dimension

Leveys

Bespoke

Valmistajan ohjeistus

1200mm wide x 20000mm high maximum panel dimension

Takuun kuvaus

Two year

Uniclass

Pr_25_71_57_80 Liukuvat ja kasattavat paneeliväliseinätEnsisijainen

CAWS

L20/545 Sliding stacking panel partitions

SKU Code

100

Erittelytiedot - Sliding stacking panel partitions

Luokittelutiedot

Performance

Rw 37 dB, in accordance with BS EN ISO 140-3.
Rw 41 dB, in accordance with BS EN ISO 140-3.
Rw 43 dB, in accordance with BS EN ISO 140-3.
Rw 44 dB, in accordance with BS EN ISO 140-3.
Rw 45 dB, in accordance with BS EN ISO 140-3.
Rw 46 dB, in accordance with BS EN ISO 140-3.
Rw 47 dB, in accordance with BS EN ISO 140-3.
Rw 48 dB, in accordance with BS EN ISO 140-3.
Rw 50 dB, in accordance with BS EN ISO 140-3.
Rw 51 dB, in accordance with BS EN ISO 140-3.
Rw 52 dB, in accordance with BS EN ISO 140-3.
Rw 53 dB, in accordance with BS EN ISO 140-3.
Rw 55 dB, in accordance with BS EN ISO 140-3.
Rw 57 dB, in accordance with BS EN ISO 140-3.
Rw 58 dB, in accordance with BS EN ISO 140-3.

Ohje vaihtoehtoiseen määritykseen:

Please note the Type TL 1 'E' track single point suspension is not suitable for this rating.

Rw 60 dB, in accordance with BS EN ISO 140-3.

Ohje vaihtoehtoiseen määritykseen:

Please note the Type TL 1 'E' track single point suspension is not suitable for this rating.

Valmistajan ohjeistus

  • Can be used to limit noise transmission between rooms, using optional dense cladding, optional internal insulation. Type 100 panels have been tested to achieve sound reduction ratings of up to Rw 60 dB, measured in accordance with EN ISO 140-3.
  • Insulation typically related to panel weight. Average achieved site insulation typically less than laboratory conditions, due to flanking structures.
  • Can be used to control room sound absorption levels using optional fabric wrapped acoustic panels or optional perforated/ slotted sound absorbent boards.

Operation

E: Fully electric.

Ohje vaihtoehtoiseen määritykseen:

  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electric relocation of panels by motors within trolleys, housed within special track type.
  • Each panel requires two-point suspension.
  • Power to trolleys conducted via busbars within track.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


M: Manual.

Ohje vaihtoehtoiseen määritykseen:

  • Manual relocation of panels.
  • Seals operated by removable winding handle.


SE: Semi-electric.

Ohje vaihtoehtoiseen määritykseen:

  • Manual relocation of panels.
  • Horizontal and vertical seals activated by 24 V electric motors concealed within panel thickness.
  • Electrical supply to panels conducted through contacts in panel edge profiles.
  • Remote master switching (to be within sight of TE panel, for safe operation.
  • Mains connection by main contractor: 240 V,13 A with isolated breaker and fused spur adjacent to London Wall control box, below ceiling level and adjacent to TE panel.


Dimensions (nominal)

-

Panel (average)

-

Width

Ohje vaihtoehtoiseen määritykseen:

Up to 1230 mm (maximum). Wider panels possible to special order; insert requirements.

Height

Ohje vaihtoehtoiseen määritykseen:

Minimum: 1.5 m up to 15 m *maximum); insert requirements.

Thickness

19 mm.

Track system

-

Wall jamb and abutments

Finished to match panels as standard.

Valmistajan ohjeistus

  • Can be supplied without wall jambs in special cases.
  • Independent wall jamb available in instances where wall structure unsuitable for standard wall jamb.
  • Fixed to structural floor and soffit.

Panels

-

Construction

Internal bracket frame with double skin cladding of 19 mm thick, three layer, high density chipboard.

Finish as delivered

Back painted glass.
Client supplied fully finished boards.

Ohje vaihtoehtoiseen määritykseen:

Insert details as required.

Factory spray paint to RAL colour.

Ohje vaihtoehtoiseen määritykseen:

Insert requirement.

High pressure laminate.
Lacquered steel sheet to RAL colour.

Ohje vaihtoehtoiseen määritykseen:

Insert requirement.

Magnetic back painted glass.
Magnetic whiteboard laminate.
Perforated sound absorbent board.

Ohje vaihtoehtoiseen määritykseen:

Perforation specification by specifier; insert details as required.

Priming sheet ready for ‘on site’ decoration by others.

Ohje vaihtoehtoiseen määritykseen:

Insert details as required.

Slotted sound absorbent board.

Ohje vaihtoehtoiseen määritykseen:

Slot specification by specifier; insert details as required.

Standard laminate.
Stretch fabric system.

Ohje vaihtoehtoiseen määritykseen:

Thickness and fabric specification by specifier; insert details as required.

Veneer.

Ohje vaihtoehtoiseen määritykseen:

Insert details of species type and cut.

Whiteboard laminate.

Valmistajan ohjeistus

Where panel type varies within the partition assembly, insert identifiers for panels after each selection.

Paneelityyppi

Ohje vaihtoehtoiseen määritykseen:

Project specific, consult manufacturer and insert requirements.

Valmistajan ohjeistus

Panel type and number.

Track profile

-

Valmistajan ohjeistus

  • Selection of material and profile by manufacturer, dependent on panel weight and other parameters; consult manufacturer to confirm size.
  • Ceiling angle trim allows support of suspended ceiling edge.
  • 20 mm exposed angle trim required to avoid partition panels fouling ceiling when using TL 1 ‘E’ system single point suspension.


Track layout

TL 1 ‘E’ system.

Ohje vaihtoehtoiseen määritykseen:

  • Straight runs only, panels stacked within opening.
  • Single track, single point suspension.

TL 2 ‘Za’ system.

Ohje vaihtoehtoiseen määritykseen:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Minimal panel stack.

TL 3 ‘Zb’ system.

Ohje vaihtoehtoiseen määritykseen:

  • Straight runs only.
  • Twin point guide roller suspension.
  • Panels stacked within opening to left or right of track.

TL 4 ‘K’ system.

Ohje vaihtoehtoiseen määritykseen:

  • Panels stacked in recess cupboard.

TL 5 ‘K’ system.

Ohje vaihtoehtoiseen määritykseen:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  •  Two point suspension.

TL 6 ‘K’ system.

Ohje vaihtoehtoiseen määritykseen:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  • Stacked behind reveal, two point suspension.

TL 7 ‘K’ system.

Ohje vaihtoehtoiseen määritykseen:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  •  Stacked inside wall recess, two point suspension.

TL 8 ‘K’ system.

Ohje vaihtoehtoiseen määritykseen:

  • For 90° movement of panels away from main track, twin point cross roller suspension.
  • Stacked in branches to one or both sides.

Valmistajan ohjeistus

Please note: If Type TL1 'E' track is specified then Rw 58dB (laboratory tested) sound reduction and Rw 60dB (laboratory tested) sound reduction is not suitable.

Paloturvallisuus

To EN 13501-1, Class D.

Ohje vaihtoehtoiseen määritykseen:

As standard.

Contact manufacturer for full classification details. The classifications depend on factory of manufacture and the corresponding finish.

To EN 13501-1, Class B.

Ohje vaihtoehtoiseen määritykseen:

Contact manufacturer for full classification details. The classifications depend on factory of manufacture and the corresponding finish.

Valmistajan ohjeistus

  • Particular fire rating may not be available in all panel types and finishes; consult manufacturer prior to specification.
  • Available with optional fire separation construction.

FireRating

Not fire rated.

Ohje vaihtoehtoiseen määritykseen:

Standard.

30 minute fire rated.
60 minute fire rated (no pass door).

Partition assembly

Refer to manufacturer drawing (SL – 101, SL – 102 and SL – 103), for disposition of specified elements.

Panel vertical edge type

Exposed satin-anodized aluminium.
Exposed powder-coated aluminium.
Concealed satin-anodized aluminium.
Concealed powder-coated aluminium.

Panel stacking arrangement

Bi–parting.
Double stack.
Single stack.

Ceiling angle trim

None.
Exposed 20 mm from underside of ceiling (TL1 'E' track only).

Ohje vaihtoehtoiseen määritykseen:

Single point suspension only.

Flush with underside of ceiling.

Ohje vaihtoehtoiseen määritykseen:

Two point suspension only.

Track finish

White.

Ohje vaihtoehtoiseen määritykseen:

As standard, spray painted.

Plain RAL colour.

Ohje vaihtoehtoiseen määritykseen:

Insert requirement.

Supporting structure

Ohje vaihtoehtoiseen määritykseen:

Project specific, consult manufacturer and insert requirements.

Valmistajan ohjeistus

Type of structure supporting the weight of the folding wall above the head track.

Barriers in ceiling void

Required.
Not required.

Baffle

Required.
Not required.

Vision panels

Required.
Not required.
As drawing.

Kestävyystiedot

Sisältää Red List -materiaaleja

No

Materiaalin alkuperämaa

-

Valmistajan ohjeistus

Germany, Holland or Sweden

Tuotteen valmistusmaa

-

Valmistajan ohjeistus

Germany, Holland or Sweden

Materiaali

Aluminium
Glass

Kierrätettävyys

Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production

Kierrätetty sisältö

17.5 %

Odotettu Elämä

30 year

Dokumentit

Type 100 Product

Type 100 Product

Uutiset

Movawall Systems Ltd - Showroom

Movawall Systems Ltd - Showroom

Type 100 Fully Electric - London School of Hygiene

Type 100 Fully Electric - London School of Hygiene

Type 100 - Longwater Reading

Type 100 - Longwater Reading

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE and Type G100 Combination - QEII Centre

Type 100SE - Radiation Protection

Type 100SE - Radiation Protection

Type G100 and Type 100SE Combination - Taunton School

Type G100 and Type 100SE Combination - Taunton School

Type 100 - Salesforce Tower

Type 100 - Salesforce Tower

Type 100 - Devonshires, Leeds

Type 100 - Devonshires, Leeds

Type 100SE - Financial Services Firm, London

Type 100SE - Financial Services Firm, London

Samankaltaiset tuotteet valmistajalta Movawall Systems Ltd

Type 80 movable acoustic wall

Type 80 movable acoustic wall

Type Float   - Gliding Wall Panels

Type Float - Gliding Wall Panels

Type G200 framed glass sliding partition

Type G200 framed glass sliding partition

Type GG / GG Plus glazed movable wall

Type GG / GG Plus glazed movable wall

Type RG Plus glazed acoustic movable wall

Type RG Plus glazed acoustic movable wall

Type Slide   - Sliding Wall Partitions

Type Slide - Sliding Wall Partitions