NBS Source
Olen tuotetoimittaja

MechSlip Brick Cladding

Valmistajan varmentama 7 kuukautta sitten

Ash & Lacy Tuotesertifikaatit:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Sertifikaatin tyyppi

  • Environmental Product Declaration

    Sertifikaatin tyyppi

Mechanically fixed brick cladding system.

Siirry kohtaan:
BOS
+44 (0)121 525 1444 Verkkosivu

Käyttötarkoitus

For external walls of domestic and non-domestic buildings, above the damp-proof course level in areas with non-severe exposure to chemicals. Suitable for both new build and refurbishment projects. Suitable building substrates include:

  • Steel frame.
  • Concrete frame.
  • Brickwork.
  • Dense concrete blockwork (minimum 1450 kg/m³).
  • Lightweight steel framing.
  • Existing masonry.
  • Timber frame.

Kuvaus

Mechanically fixed, real brick facade system comprising 28mm thick brick slips and aluminium support rails. Available in an extensive range of colours, textures and brick sizes.

Features and benefits:

  • Lightweight - over 50% lighter than traditional masonry, reducing the structural load.
  • Fully mechanically secured brick slips.
  • Non-combustible system components.
  • Versatile brick finishes and detailing options.
  • Metric, linear and imperial brick sizes.
  • Pre-spaced mortar joints.
  • Cost effective for projects where traditional methods of construction are difficult to facilitate.
  • Simple installation using aerial work platforms, reducing the need for scaffolding.
  • Non-weather dependent installation.
  • Can be fitted seamlessly to Ash & Lacy's AxiAL or AxiAL+ rainscreen support systems.
  • Tested to the Centre for Window and Cladding Technology (CWCT) standards.
  • Fire tested to EN13501-1 - A1.
  • BS8414 test data available.
  • BBA Certified

Components:

- Mechanical system components:

  • Starter rail – 23.5 x 18.5 mm (h x w). Available in 3000mm lengths.
  • Intermediate rail – 23 x 11.1 mm (h x w). Available in 3000mm lengths.
  • Top rail – 31 x 18.5 mm (h x w). Available in 3000mm lengths.

- Brick system components:

  • Stretcher and header bricks.
  • Soldier bricks.
  • Corner bricks.
  • Solid aluminium 'brick slip' for fixing external loads.
  • Perforated aluminium 'brick slip' for ventilation.

Yleistiedot

Väri

Viimeistely

Other

Materiaali

Clay

Aluminium

Stainless steel

Muoto

Other

Rectangle

Pituus

215 mm

Leveys

28 mm

Korkeus

65 mm

Takuun kuvaus

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsEnsisijainen

CAWS

H92/120 Rainscreen cladding

SKU Code

unknown

Erittelytiedot - Drained and back-ventilated rainscreen cladding systems

Luokittelutiedot

System performance

Fire performace: Reaction to fire to EN 13501-1:2018, Class A1.

Thermal insulation

-

Valmistajan ohjeistus

The use of Rockwool insulation is recommended by the manufacturer in association with MechSlip. Insert requirements.

Secondary support structure

Horizontal application - AxiAL AX1 Support System, anodized aluminium brick slip support rails fixed to vertical support mullions on wall brackets.

Ohje vaihtoehtoiseen määritykseen:

For fixing to a masonry substrate.

Vertical application - AxiAL AX2 Support System, anodized aluminium brick slip support rails fixed to horizontal support mullions on wall brackets.

Ohje vaihtoehtoiseen määritykseen:

For fixing to a masonry substrate.

Valmistajan ohjeistus

For steel frames, dependent on SFS stud centres, additional ‘top hat’ rails are available if required to fix support rails back to the substrate. Consult manufacturer.

Cavity fire barriers

-

Horizontal

-

Valmistajan ohjeistus

Fire cavity barriers are not included within the MechSlip system and should be specified and designed by a

qualified engineer.

Vertical

-

Valmistajan ohjeistus

Fire cavity barriers are not included within the MechSlip system and should be specified and designed by a

qualified engineer.

Cladding panels

-

Material

Fired clay brick slips.

Panel joints

Brick spacers and Parex Easipoint Historic pointing mortar.

Ohje vaihtoehtoiseen määritykseen:

A bucket handle joint profile is recommended. Insert mortar colour requirements.

Reveals

Brick slip reveals.
Metal flashing.

System accessories

Metal finishing trims.
Vent brick slips.

Ohje vaihtoehtoiseen määritykseen:

Vent brick slips must be installed in required areas to accommodate ventilated facade criteria.

Aluminium brick slips.

Ohje vaihtoehtoiseen määritykseen:

Aluminium extruded brick slips must be installed in areas

where an external load (camera, light, etc.) will be installed on

the facade.

Third-party certification

BBA Agrément Certificate.

Ohje vaihtoehtoiseen määritykseen:

MechSlip has undergone BBA testing and assessment to produce both an Ash & Lacy branded certificate (20/5787), and an Ibstock Kevington branded certificate (20/5839).

Colour

Ohje vaihtoehtoiseen määritykseen:

Over 300 colours available. Colour can be matched to client specifications. Consult manufacturer and insert requirements.


Size

215 x 65 mm.
Other.

Ohje vaihtoehtoiseen määritykseen:

Imperial or linear sizes can be specified (supplied to the published size tolerances for each brick type). Insert requirements.

Paino

51.5 kg/m² (approximately).

Valmistajan ohjeistus

System weight.

Thermal conductivity

0.71 W/m·K (for clay brick slips).

Iskunkestävyys

Class 1 in accordance with CWCT standard test methods.

Tuulenkestävyys

±2400 Pa serviceability, ±3600 Pa safety in accordance with CWCT standard test methods.

Valmistajan ohjeistus

Wind resistance safety.

Watertightness

600 Pa, in accordance with CWCT standard test methods.

Freeze-thaw resistance

To ETAG 017, Pass; To BS EN 771-1, F2.

HygrothermalRating

To ETAG 034, Pass.

Valmistajan ohjeistus

Hygrothermal testing.

Fixings

Stainless steel.

Ohje vaihtoehtoiseen määritykseen:

Rail/mullion fix screws, thermal pad, fixing screws, and bracket/wall fix screws are supplied where necessary.

Fixings, brackets and support rails are supplied by Ash & Lacy. The quantity calculated on an individual project-by-project

basis.

Kestävyystiedot

Selkeys vähähiiliseen suunnitteluun

NBS LCA auttaa rakennusalan ammattilaisia mittaamaan ympäristövaikutuksia ja löytämään vähähiilisiä tuotteita kestävämpiin projekteihin.

Tutustu NBS LCA:han
LCA-havainnollistus

Sisältää Red List -materiaaleja

No

Materiaalin alkuperämaa

United Kingdom

Tuotteen valmistusmaa

United Kingdom

Materiaali

Clay
Aluminium
Stainless steel

Tuotesertifikaatit

BIM-objektit

BOS

NBS BIM-objektistandardi

Tämä BIM-objekti on tuotettu täyttämään NBS BIM-objektistandardin vaatimukset.

Lue lisää NBS BIM-objektistandardista.

AlustaYhteensopivaVersio
Revit
-

1

IFC
-

1

Tuotesertifikaatit

BBA Agrément Certificate

BBA Agrément Certificate

BBA Certificate - Mechslip Brick Cladding

Environmental Product Declaration

Environmental Product Declaration

EPD - Aluminium Support Systems for Rainscreen Cladding

Dokumentit

Mechslip Brick Cladding

Mechslip Brick Cladding

AxiAL+ Technical Brochure

AxiAL+ Technical Brochure

AxiAL Rainscreen Support Systems

AxiAL Rainscreen Support Systems

CPD-materiaalit

The Future of Brick Facades

The Future of Brick Facades

Uutiset

10 Brindley Place, Birmingham

10 Brindley Place, Birmingham

340a Clapham Road

340a Clapham Road

Samankaltaiset tuotteet valmistajalta Ash & Lacy

LineAL-F Aluminium Cladding System

LineAL-F Aluminium Cladding System

NaturAL-X Brick Cladding

NaturAL-X Brick Cladding

VariAL-CF3 Aluminium Cladding System

VariAL-CF3 Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-TF Metal Cladding System

VariAL-TF Metal Cladding System