Verified by manufacturer 16 hours ago
BBA Agrément Certificate
Certificate type
An inverted EPDM warm roof system.
For roofs with regular traffic, or roofs in severe weather climates.
The Inverted System is a variation of the conventional ballasted system. It is particularly suitable for roofs with regular traffic, or roofs in severe weather climates. It can be applied on any building that can accommodate the extra load of the ballast and where the roof slope does not exceed 10%.
Features and benefits:
System components:
Color | Black |
Material | Rubber |
Shape | Rectangle |
Length | 30500 mm |
Width | 3050 mm 6100 mm 9150 mm 12200 mm 15250 mm |
Uniclass | |
CAWS | J42/12 Inverted roof covering J42/120 Inverted roof covering |
Classification data | |
Insulation | |
Type | Extruded polystyrene (XPS) boards. Guidance for specification option: Insert thickness requirements. |
Attachment | Loose laid over the RubberGard EPDM membrane. |
Waterproof covering | |
Type | RubberGard™ EPDM LSFR Roofing Membrane 1.1 mm. RubberGard™ EPDM LSFR Roofing Membrane 1.5 mm. Manufacturer guidance100% cured non-reinforced, Ethylene-Propylene-Diene Terpolymer (EPDM) synthetic rubber, manufactured in an ISO 9001 and ISO 14001 registered facility. Minimum unspliced width of 3.05 m. Specification compliance: UL Classified/ FM Approved. ASTM D 4637/ EN 13956 (CE Mark). 7500 hrs of Artificial Ageing as per EN 1297. |
Attachment | Loose laid. Guidance for specification option: Over rough substrates install a geotextile protection mat, 200 g/m² (minimum) weight, prior to laying the RubberGard EPDM membrane. |
Joints | Lap splices: 100 mm minimum overlap with 76 mm QuickSeam Splice Tape. |
Upper protection layer | Water flow reducing layer (WFRL). Guidance for specification option: As recommended by the insulation supplier. It will be placed on the insulation layer prior to installation of ballast or slabs on supports. |
Surface protection | Geotextile protection mat, 200 g/m² (minimum) weight, and ballast layer, 50 kg/m² (minimum) weight. |
System accessories | QuickSeam Splice Tape. QuickSeam FormFlash. QuickSeam Flashing. QuickSeam SA Flashing. QuickSeam Reinforced Perimeter Fastening Strip. QuickSeam Universal Pipe Flashing. QuickSeam Conduit Flashing. QuickSeam Penetration Pocket. QuickSeam Walkway Pad. QuickPrime Plus. Lap Sealant HS. All Purpose (AP) Fasteners. Heavy Duty (HD) Fasteners. Splice Wash (SW-100). Cleaner C-20. Water-Block Seal (S-20). Pourable Sealer S-10 (Parts A & B). Coiled Metal Batten Strip. Metal Batten Strip. Termination Bar. |
Corners | QuickSeam FormFlash (external corners) and folded internal corners. |
Pipes | Pipe penetrations: QuickSeam FormFlash. Pipe penetrations: QuickSeam Pipe boots and Conduit Flashing. |
Outlets | Drains: Install Water Block Sealant between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring. Drains: Insert outlet bedded on Water Block Sealant. Secure and flash with QuickSeam FormFlash or SA Flashing. |
Walls | Wall terminations: Termination bar, fastened with Water Block Sealant and Lap Sealant HS installed along top edge. Guidance for specification option: @200mm (maximum) o.c. Wall terminations: Metal batten bar, fastened with surface mounted or inserted metal counter flashing protection. Guidance for specification option: @150mm (maximum) o.c. Wall terminations: Metal capping or concrete coping stones. Wall termination: Preformed metal edge trim. |
Material | Rubber |
| Platform | Compatible | Version |
|---|---|---|
| - | 1 |
Rhenofol® PVC Single Ply Roofing System (Adhered)
Rhenofol® PVC Single Ply Roofing System (for Green Roofs And Roof Terraces)
Rhenofol® PVC Single Ply Roofing System (Mechanically Attached) - Single Ply PVC-P Warm Roof System
RubberGard™ EPDM SA Single Ply Roofing System (Self Adhesive) - Self-adhesive EPDM Single Ply Roofing
RubberGard™ EPDM Singel Ply Roofing System (Ballasted)
RubberGard™ EPDM Single Ply Roofing System (Fully Adhered)
RubberGard™ EPDM Single Ply Roofing System (Mechanically Attached)
UltraPly™ TPO Single Ply Roofing System (Inverted Roof)
UltraPly™ TPO Single Ply Roofing System (Adhered)
UltraPly™ TPO Single Ply Roofing System (Ballasted)