Verified by manufacturer 1 month ago
Upgrade steel frames with Licatatherm EWI using mineral wool, flexible basecoat, mesh and clay brick slips finish for stronger durability and improved thermal performance in one solution.
The system is for installation above damp proof course level on external sheathed light gauge steel frame supporting walls.
Suitable for a range of projects including residential buildings, schools, student accommodation, remediation, and high raise projects, in existing and new buildings.
Licatatherm clay brick slip System has been designed for steel frame substrates on a sheathing board. The system consists of mineral wool insulation boards which are mechanically and adhesively fixed, mechanically fixed through the basecoat, and reinforcement mesh to the supporting wall. A secondary layer of basecoat, is applied followed by the adhesive mortar and pointing mortar that gives the finish clay brick slips a realistic image. Featuring great durability, water repellent surface and protection against algae and mould. With increased strength and crack resistance, due to the glass fibre mesh. The system fire classification is A1 in accordance with BS EN 13501-1, and tested 120’ fire resistance both directions in accordance with BS EN 1363-1 & BS EN 1364-1, With a wide range of finishes and colours, bespoke, special shapes and dimensions available.
LicataTherm External wall insulation system for light steel frame substrates onto 12 mm A1 sheathing board, incorporating an A1 non-combustible mineral wool insulation board, this system achieves a system fire classification of A1 to BS EN 13501-1, allowing it to be used on a building of any height.
Engineered to excel in the UK climate, it has a range of clay brick slips in a typical size of 215 x 65 x 15 mm as finish coat. The thermal benefits come from the mix of components of the system. The direct fix application allows the system to be directly mechanically fixed and with adhesive, removing the need for a cavity and the cavity fire-stopping behind the insulation
Features and benefits:
Color | Beige Black Blue Brown Cream |
Finish | Smooth Natural Brick |
Material | Clay |
Shape | Rectangle Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: The system shall be installed in accordance with the appropriate sections of all current relevant codes of practice, Building Regulations, and manufacturer's installation instructions for product supplied by the company. The works shall be installed by a LBS Registered Contractor, and, as agreed in the contract, the LBS 25 Year Warranty shall be issued to the Building Owner from the date of final completion. This system warranty is conditional upon the full system being purchased from LBS and installed in accordance with the above specification. Substitution of any products, or installation by means other than those described, will invalidate the warranty offered. The warranty offered is subject to the terms and conditions set out in the certificate of warranty, available upon request. |
Uniclass | |
CAWS | M21/210 Rendered external wall insulation systems M21/20 External wall insulation systems |
Classification data | |
System performance | Fire performance: A1 in accordance with BS EN 13501-1, and tested 120’ fire resistance both directions in accordance with BS EN 1363-1 and BS EN 1364-1. Durability: 30 years. Impact resistance Category I. |
Preparation | A pre-installation survey of the property must be carried out by the approved installers to determine suitability for treatment and the need for any necessary repairs to the building substrate before application of the system. The survey should include tests conducted on the walls of the building to determine the pull-out resistance of the proposed mechanical fixings. For cement board substrates, if Licata boards are used there is no need of pullout tests as already tested and installation instructions, patterns and approved fixings will be supplied. All modifications, such as alterations to external plumbing and necessary repairs to the building substrate, must be completed before installation of the system commences. Surfaces should be sound, clean, and free from loose material. The flatness of surfaces must be checked; this may be achieved using a straight-edge tool spanning the storey height. Any excessive irregularities, i.e. greater than 10 mm must be made good prior to installation, to ensure that the insulation slabs are installed with a smooth, in-plane finished surface. Where surfaces are covered with an existing render, it is essential that the bond between the background and the render is adequate. All loose areas should be hacked off and reinstated. On existing buildings, purpose-made sills and copings must be fitted to extend beyond the finished face of the system. New buildings should incorporate suitably deep sills and copings. In new buildings, internal wet work (e.g. screeding or plastering) should be completed and allowed to dry prior to the application of the system. |
Support rails and brackets | |
Boards | |
Material | A1 non-combustible fibre cement board. |
Insulation | |
Material | Mineral wool. |
Adhesive | Raso Top 800 Adhesive. |
Fire barriers and stops | |
Material | Not required. |
Beads and trims | Licata meshed corner bead with mesh. Licata PVC stop bead with mesh. Licata APU frameseal bead with mesh. |
Movement joints | |
Sealant | Licata foam tape. |
Render carrier or reinforcement | |
Material | Alkali resistant reinforcing fibreglass mesh. Guidance for specification option: Nominal weight of 160 g/m². |
Mesh size | 160 g/m². Guidance for specification option: Supplied in 50 x 1 m rolls. |
Render | |
Decorative finish | Clay brick slips applied with Super S1 adhesive and finished with Lime Green brick slip jointing mortar. Guidance for specification option:
|
Colour | Guidance for specification option: Wide range of colours and size formats. Consult manufacturer for options and insert requirements. |
System accessories | Aluminium starter track. Fungicidal wash. Licata compression band. |
System completion | Final checking and warranty issue. |
Standard | To EAD 040083-000404 and EAD 350140-00-1106. |
Samples required | Product samples. |
Material | Clay |
LicataTherm EcoPure Lime-based External Wall Insulation System
LicataTherm Masonry EPS Acrylic Render External Wall Insulation System - EWI with Kingspan K5 Insulation
LicataTherm Masonry EPS Mineral Render External Wall Insulation System
LicataTherm Masonry EPS Silicone Render External Wall Insulation System - External Wall Insulation System
LicataTherm Steel Frame Mineral Wool Mineral Brick Slips External Wall Insulation System - External Wall Insulation System onto SFS
LicataTherm Steel Frame Mineral Wool Silicone Render External Wall Insulation System - External wall insulation system onto SFS
LicataTherm Timber Frame Mineral Wool External Wall Insulation System - All Finishes - External Wall Insulation System