RESITRIX® SKP/SKW Warm Roof Adhered - Single Layer Roof Covering System

Verified by manufacturer 2 months ago

Full bond

Carlisle Construction Materials Limited Variant:
Product certifications:
  • EPD

    EPD

    Certificate type

  • DoP

    DoP

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • DoP

    DoP

    Certificate type

  • EPD

    EPD

    Certificate type

  • DoP

    DoP

    Certificate type

  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • EPD

    EPD

    Certificate type

A high-performance single-layer waterproofing solution that combines the durability and flexibility of EPDM rubber with the proven adhesion properties of polymer-modified bitumen.

Jump to:
+44 (0)1623 627285 Website

Application

Designed for both new build and refurbishment projects.

  • Particularly suited to warm roof constructions due to its compatibility with a wide range of insulation substrates and vapour control layers.
  • Fully compatible with bitumen substrates.
  • Suitable for a wide range of insulation materials and roof deck types.
  • Compatible with green roof and landscaped roof constructions using root-resistant membrane options.

Description

The RESITRIX® Warm Roof System is a high-performance single-layer waterproofing solution that combines the durability and flexibility of EPDM rubber with the proven adhesion properties of polymer-modified bitumen. Designed for both new-build and refurbishment projects.

It is particularly suited to warm roof constructions due to its compatibility with a wide range of insulation substrates and vapour control layers.

The system offers exceptional long-term performance, with independent testing confirming a service life in excess of 70 years. RESITRIX membranes remain flexible down to -40°C, resist UV radiation, ozone, weathering, chemicals, and environmental pollutants, and provide fully welded watertight seams without the need for naked flames during installation.

Features and benefits:

  • Single-layer EPDM waterproofing membrane.
  • 100% hot-air welded seams with visible weld bead for immediate quality inspection.
  • Seam integrity can be visually verified without specialist testing equipment.
  • Independently verified service life exceeding 70 years.
  • Resistant to UV radiation, ozone, infrared radiation, and extreme weather conditions.
  • Permanently elastic with elongation at break up to 600%.
  • Maintains flexibility at temperatures down to -40°C.
  • Practically shrink-free due to integrated glass fibre reinforcement.
  • Hot-air welded installation with no naked flames.
  • Lightweight, easy-to-handle membrane rolls.
  • Can be installed directly onto existing bituminous roofing systems.
  • Free from plasticisers, halogens, and heavy metals.
  • Classified as non-toxic throughout its service life.
  • Recyclable materials.
  • Supported by Environmental Product Declarations (EPDs) and sustainability certifications.

General information

Color

Black

Finish

Textured

Material

EPDM

Shape

Rectangle

Square

Other

Length

10000 mm

Width

1000 mm

Height

Bespoke

Warranty description

-

Manufacturer guidance

Guarantee options could include ‘Product’, ‘Product and Workmanship’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Carlisle specification and being installed by a Carlisle Approved installer. For full details and further information regarding guarantees and alternative systems please contact Carlisle info.uk@ccm-europe.com

Uniclass

Ss_30_40_30_80 Single layer sheet warm roof covering systemsPrimary

CAWS

J42/10 Warm deck roof covering

J42/110 Warm deck roof covering

Specification data - Single layer sheet warm roof covering systems

Classification data

Preparation

-

Horizontal work

FG 35 surface primer.

Guidance for specification option:

Black, solvent-containing primer based on synthetic rubber and resins.

  1. For priming substrate surfaces for self-adhesive RESITRIX® waterproofing membranes on:
    • Metallic substrates, uncoated;
    • Bituminous materials;
    • Wooden materials;
    • Timber/timber materials;
    • Plastics;
    • Insulation boards (apart from unfaced EPS foam boards).
  2. For priming substrate surfaces for ALUTRIX® 600 or ALUTRIX® FR self-adhesive aluminium vapour-barrier membranes on bituminous materials, timber materials and solid materials.

FG 40 surface primer.

Guidance for specification option:

For full-surface priming of substrate surfaces for direct self-adhesive laying of RESITRIX® SK W Full Bond on thermal insulation made from unfaced polystyrene foam boards without factory fitted bitumen lamination or bitumen deck.

Colour: blue.

Not required.

Manufacturer guidance

Where appropriate, lightly-soiled substrates to be cleaned using RESITRIX® G500 cleaner. See System accessories.

Skirtings and vertical work

As Horizontal work.

Air and vapour control layer

-

Type

ALUTRIX® 600 vapour barrier.

Guidance for specification option:

Consult manufacturer's datasheet for details.

Attachment

Self-adhesive.

Insulation

-

Type

CCM T INS-25 tissue-face thermal insulation, 25 mm thick.

Guidance for specification option:

R-value: 0.96 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-30 tissue-face thermal insulation, 30 mm thick.

Guidance for specification option:

R-value: 1.15 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-40 tissue-face thermal insulation, 40 mm thick.

Guidance for specification option:

R-value: 1.50 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-50 tissue-face thermal insulation, 50 mm thick.

Guidance for specification option:

R-value: 1.90 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-60 tissue-face thermal insulation, 60 mm thick.

Guidance for specification option:

R-value: 2.30 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-70 tissue-face thermal insulation, 70 mm thick.

Guidance for specification option:

R-value: 2.65 m²K/W.

Thermal conductivity: 0.026 W/m·K.

CCM T INS-80 tissue-face thermal insulation, 80 mm thick.

Guidance for specification option:

R-value: 3.20 m²K/W.

Thermal conductivity: 0.025 W/m·K.

CCM T INS-90 tissue-face thermal insulation, 90 mm thick.

Guidance for specification option:

R-value: 3.60 m²K/W.

Thermal conductivity: 0.025 W/m·K.

CCM T INS-100 tissue-face thermal insulation, 100 mm thick.

Guidance for specification option:

R-value: 4.00 m²K/W.

Thermal conductivity: 0.025 W/m·K.

CCM T INS-110 tissue-face thermal insulation, 110 mm thick.

Guidance for specification option:

R-value: 4.40 m²K/W.

Thermal conductivity: 0.025 W/m·K.

CCM T INS-120 tissue-face thermal insulation, 120 mm thick.

Guidance for specification option:

R-value: 5.00 m²K/W.

Thermal conductivity: 0.024 W/m·K.

CCM T INS-130 tissue-face thermal insulation, 130 mm thick.

Guidance for specification option:

R-value: 5.40 m²K/W.

Thermal conductivity: 0.024 W/m·K.

CCM T INS-140 tissue-face thermal insulation, 140 mm thick.

Guidance for specification option:

R-value: 5.80 m²K/W.

Thermal conductivity: 0.024 W/m·K.

CCM T INS-150 tissue-face thermal insulation, 150 mm thick.

Guidance for specification option:

R-value: 6.25 m²K/W.

Thermal conductivity: 0.024 W/m·K.

CCM T INS-160 tissue-face thermal insulation, 160 mm thick.

Guidance for specification option:

R-value: 6.65 m²K/W.

Thermal conductivity: 0.024 W/m·K.

Manufacturer guidance

  • Compression strength: exceeds 150 kPa at yield.
  • Moisture vapour resistance: installed value of 15 MN·s/g.
  • Fire performance: Class 1 to BS 476-7.
  • Dimensions (length x width): 1200 x 600 mm.
  • Available as tapered insulation board.
  • Facing: perforated mineral coated glass fibre tissue to both sides.
  • Certification: LPCB (LPS 1181) approved.

Attachment

Manufacturer's standard.

Waterproof covering

-

Type

RESITRIX® SK W Full Bond.

Attachment

Self-adhesive.

Joints

Welded jointing of waterproof membrane.

Surface protection

RESITRIX Walkway.

Guidance for specification option:

A slip-resistant safety overlay based on EPDM with an additional glass mesh reinforcement for perforation protection and dimensional stabilisation, as well as a self-adhesive polymer bitumen layer on the underside.

Consult manufacturer's literature for details.

Not required.

System accessories

Lightning conductor clips.
RESIFLEX® SK expansion joint sealing strips.
RESIFLEX® 3D expansion joint sealing strips.
Pipe penetration sleeves (5–30 mm).
Pipe penetration sleeves (35–100 mm).
Ready-made detailing.

Guidance for specification option:

  • Ready-made punched parts for sealing round fitted parts and for constructing any corners. The cut pieces are punched from the RESIFLEX® SK self adhesive expansion-joint sealing strip.
  • Available in round, kidney and tongue/ oval shapes for a range of applications; consult manufacturer and insert requirements.

RESITRIX® G500 cleaner.

Manufacturer guidance

Consult manufacturer's literature for details.

See also Drainage below for related accessories.

Drainage

RESITRIX® self-adhesive EPDM drain outlet, 38/ 50 mm (19487).
RESITRIX® self-adhesive EPDM drain outlet, 58/ 70 mm (19489).
RESITRIX® self-adhesive EPDM drain outlet, 78/ 90 mm (19496).
RESITRIX® self-adhesive EPDM drain outlet, 96/ 105 mm (19489).
CCM stainless steel vertical roof outlet.

Guidance for specification option:

Insert requirements.

Range of standard external diameters and spigot sizes available. Other sizes and/ or an SBS membrane flange are available to order

CCM sump outlet drain.
CCM parapet roof outlet, with angled base plate.

Guidance for specification option:

Insert requirements.

Range of standard external diameters and spigot lengths available.

CCM leaf guard, universal.

Guidance for specification option:

Stainless steel leaf guard to suit all sizes of vertical roof outlets listed above.

CCM parapet leaf guard.

Guidance for specification option:

Stainless steel leaf guard to suit the 110 mm parapet roof outlets listed above.

CCM monsoon leaf guard.
CCM soil vent pipe cover.

Guidance for specification option:

Stainless steel soil vent pipe cover to suit 110 mm pipes. Supplied with RESITRIX® membrane flange.

Not required.

Sustainability data

Clarity for low-carbon design

NBS LCA helps construction professionals measure environmental impact and identify low-carbon emission products for more sustainable projects.

Explore NBS LCA
LCA illustration

Material

EPDM

Product certifications

Product certifications

EPD

EPD

RESITRIX® SK Partial Bond - Environmental Product Declaration EPD

DoP

DoP

RESITRIX® SK Partial Bond - Declaration of Performance (DoP)

BBA Agrément Certificate

BBA Agrément Certificate

RESITRIX® SK W Full Bond - BBA 06/4329

DoP

DoP

RESITRIX® SK W Full Bond - Declaration of Performance (DoP)

EPD

EPD

RESITRIX® SK W Full Bond - Environmental Product Declaration EPD

DoP

DoP

ALUTRIX® 600 - Declaration of Performance (DoP)

BBA Agrément Certificate

BBA Agrément Certificate

ALUTRIX® 600 BBA

EPD

EPD

ALUTRIX® 600 - Environmental Product Declaration EPD

Literature

RESITRIX® FG 35 - Technical Datasheet

RESITRIX® FG 35 - Technical Datasheet

RESITRIX® G500 - Technical Datasheet

RESITRIX® G500 - Technical Datasheet

RESITRIX® Lightning Conductor Clips - Technical Datasheet

RESITRIX® Lightning Conductor Clips - Technical Datasheet

RESITRIX® Pipe Sleeves - Technical Datasheet

RESITRIX® Pipe Sleeves - Technical Datasheet

RESITRIX® Product Catalogue

RESITRIX® Product Catalogue

RESITRIX® SK Partial Bond Data Sheet

RESITRIX® SK Partial Bond Data Sheet

RESITRIX® SK W Full Bond Data Sheet

RESITRIX® SK W Full Bond Data Sheet

RESITRIX® Walkway Flyer

RESITRIX® Walkway Flyer

RESITRIX® SKW SKP BREEAM Guide

RESITRIX® SKW SKP BREEAM Guide

RESITRIX® Specification Guidelines

RESITRIX® Specification Guidelines

RESITRIX® Installation Instructions

RESITRIX® Installation Instructions

RESITRIX® Installation Do's & Don'ts

RESITRIX® Installation Do's & Don'ts

ALUTRIX® 600/ ALUTRIX® FR - Technical Data Sheet

ALUTRIX® 600/ ALUTRIX® FR - Technical Data Sheet

Carlisle CCM-T Tissue Faced PIR Insulation

Carlisle CCM-T Tissue Faced PIR Insulation

Case studies

Earth Trust, England

Earth Trust, England

The Macallan Distillery, Scotland

The Macallan Distillery, Scotland