Black
Verified by manufacturer 2 months ago
Full bond
EPD
Certificate type
DoP
Certificate type
BBA Agrément Certificate
Certificate type
DoP
Certificate type
EPD
Certificate type
DoP
Certificate type
BBA Agrément Certificate
Certificate type
EPD
Certificate type
A high-performance single-layer waterproofing solution that combines the durability and flexibility of EPDM rubber with the proven adhesion properties of polymer-modified bitumen.
Designed for both new build and refurbishment projects.
The RESITRIX® Warm Roof System is a high-performance single-layer waterproofing solution that combines the durability and flexibility of EPDM rubber with the proven adhesion properties of polymer-modified bitumen. Designed for both new-build and refurbishment projects.
It is particularly suited to warm roof constructions due to its compatibility with a wide range of insulation substrates and vapour control layers.
The system offers exceptional long-term performance, with independent testing confirming a service life in excess of 70 years. RESITRIX membranes remain flexible down to -40°C, resist UV radiation, ozone, weathering, chemicals, and environmental pollutants, and provide fully welded watertight seams without the need for naked flames during installation.
Features and benefits:
Color | Black |
Finish | Textured |
Material | EPDM |
Shape | Rectangle Square Other |
Length | 10000 mm |
Width | 1000 mm |
Height | Bespoke |
Warranty description | Manufacturer guidanceGuarantee options could include ‘Product’, ‘Product and Workmanship’ Guarantees. All guarantees available for this system are subject to the works being carried out in accordance with the Carlisle specification and being installed by a Carlisle Approved installer. For full details and further information regarding guarantees and alternative systems please contact Carlisle info.uk@ccm-europe.com |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Classification data | |
Preparation | |
Horizontal work | FG 35 surface primer. Guidance for specification option: Black, solvent-containing primer based on synthetic rubber and resins.
FG 40 surface primer. Guidance for specification option: For full-surface priming of substrate surfaces for direct self-adhesive laying of RESITRIX® SK W Full Bond on thermal insulation made from unfaced polystyrene foam boards without factory fitted bitumen lamination or bitumen deck. Colour: blue. Not required. Manufacturer guidanceWhere appropriate, lightly-soiled substrates to be cleaned using RESITRIX® G500 cleaner. See System accessories. |
Skirtings and vertical work | As Horizontal work. |
Air and vapour control layer | |
Type | ALUTRIX® 600 vapour barrier. Guidance for specification option: Consult manufacturer's datasheet for details. |
Attachment | Self-adhesive. |
Insulation | |
Type | CCM T INS-25 tissue-face thermal insulation, 25 mm thick. Guidance for specification option: R-value: 0.96 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-30 tissue-face thermal insulation, 30 mm thick. Guidance for specification option: R-value: 1.15 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-40 tissue-face thermal insulation, 40 mm thick. Guidance for specification option: R-value: 1.50 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-50 tissue-face thermal insulation, 50 mm thick. Guidance for specification option: R-value: 1.90 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-60 tissue-face thermal insulation, 60 mm thick. Guidance for specification option: R-value: 2.30 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-70 tissue-face thermal insulation, 70 mm thick. Guidance for specification option: R-value: 2.65 m²K/W. Thermal conductivity: 0.026 W/m·K. CCM T INS-80 tissue-face thermal insulation, 80 mm thick. Guidance for specification option: R-value: 3.20 m²K/W. Thermal conductivity: 0.025 W/m·K. CCM T INS-90 tissue-face thermal insulation, 90 mm thick. Guidance for specification option: R-value: 3.60 m²K/W. Thermal conductivity: 0.025 W/m·K. CCM T INS-100 tissue-face thermal insulation, 100 mm thick. Guidance for specification option: R-value: 4.00 m²K/W. Thermal conductivity: 0.025 W/m·K. CCM T INS-110 tissue-face thermal insulation, 110 mm thick. Guidance for specification option: R-value: 4.40 m²K/W. Thermal conductivity: 0.025 W/m·K. CCM T INS-120 tissue-face thermal insulation, 120 mm thick. Guidance for specification option: R-value: 5.00 m²K/W. Thermal conductivity: 0.024 W/m·K. CCM T INS-130 tissue-face thermal insulation, 130 mm thick. Guidance for specification option: R-value: 5.40 m²K/W. Thermal conductivity: 0.024 W/m·K. CCM T INS-140 tissue-face thermal insulation, 140 mm thick. Guidance for specification option: R-value: 5.80 m²K/W. Thermal conductivity: 0.024 W/m·K. CCM T INS-150 tissue-face thermal insulation, 150 mm thick. Guidance for specification option: R-value: 6.25 m²K/W. Thermal conductivity: 0.024 W/m·K. CCM T INS-160 tissue-face thermal insulation, 160 mm thick. Guidance for specification option: R-value: 6.65 m²K/W. Thermal conductivity: 0.024 W/m·K. Manufacturer guidance
|
Attachment | Manufacturer's standard. |
Waterproof covering | |
Type | RESITRIX® SK W Full Bond. |
Attachment | Self-adhesive. |
Joints | Welded jointing of waterproof membrane. |
Surface protection | RESITRIX Walkway. Guidance for specification option: A slip-resistant safety overlay based on EPDM with an additional glass mesh reinforcement for perforation protection and dimensional stabilisation, as well as a self-adhesive polymer bitumen layer on the underside. Consult manufacturer's literature for details. Not required. |
System accessories | Lightning conductor clips. RESIFLEX® SK expansion joint sealing strips. RESIFLEX® 3D expansion joint sealing strips. Pipe penetration sleeves (5–30 mm). Pipe penetration sleeves (35–100 mm). Ready-made detailing. Guidance for specification option:
RESITRIX® G500 cleaner. Manufacturer guidanceConsult manufacturer's literature for details. See also Drainage below for related accessories. |
Drainage | RESITRIX® self-adhesive EPDM drain outlet, 38/ 50 mm (19487). RESITRIX® self-adhesive EPDM drain outlet, 58/ 70 mm (19489). RESITRIX® self-adhesive EPDM drain outlet, 78/ 90 mm (19496). RESITRIX® self-adhesive EPDM drain outlet, 96/ 105 mm (19489). CCM stainless steel vertical roof outlet. Guidance for specification option: Insert requirements. Range of standard external diameters and spigot sizes available. Other sizes and/ or an SBS membrane flange are available to order CCM sump outlet drain. CCM parapet roof outlet, with angled base plate. Guidance for specification option: Insert requirements. Range of standard external diameters and spigot lengths available. CCM leaf guard, universal. Guidance for specification option: Stainless steel leaf guard to suit all sizes of vertical roof outlets listed above. CCM parapet leaf guard. Guidance for specification option: Stainless steel leaf guard to suit the 110 mm parapet roof outlets listed above. CCM monsoon leaf guard. CCM soil vent pipe cover. Guidance for specification option: Stainless steel soil vent pipe cover to suit 110 mm pipes. Supplied with RESITRIX® membrane flange. Not required. |
EPD
RESITRIX® SK Partial Bond - Environmental Product Declaration EPD
DoP
RESITRIX® SK Partial Bond - Declaration of Performance (DoP)
BBA Agrément Certificate
RESITRIX® SK W Full Bond - BBA 06/4329
DoP
RESITRIX® SK W Full Bond - Declaration of Performance (DoP)
EPD
RESITRIX® SK W Full Bond - Environmental Product Declaration EPD
DoP
ALUTRIX® 600 - Declaration of Performance (DoP)
BBA Agrément Certificate
ALUTRIX® 600 BBA
EPD
ALUTRIX® 600 - Environmental Product Declaration EPD
RESITRIX® FG 35 - Technical Datasheet
RESITRIX® G500 - Technical Datasheet
RESITRIX® Lightning Conductor Clips - Technical Datasheet
RESITRIX® Pipe Sleeves - Technical Datasheet
RESITRIX® Product Catalogue
RESITRIX® SK Partial Bond Data Sheet
RESITRIX® SK W Full Bond Data Sheet
RESITRIX® Walkway Flyer
RESITRIX® SKW SKP BREEAM Guide
RESITRIX® Specification Guidelines
RESITRIX® Installation Instructions
RESITRIX® Installation Do's & Don'ts
ALUTRIX® 600/ ALUTRIX® FR - Technical Data Sheet
Carlisle CCM-T Tissue Faced PIR Insulation