Verified by manufacturer 3 months ago
10–75 mm cavity
Full fill non-ventilated cavity fire barrier manufactured from a low density stone wool.
For installation between the inner and outer substrates of a masonry facade, to reinstate the fire resistance performance of the cavity.
Tenmat’s Non-Ventilated Fire Barrier (NVFB-LD) is a full fill cavity fire barrier manufactured from a Euroclass A1 reaction to fire classified, 100 mm thick low density stone wool.
The lower density design allows the 5 mm compression requirement to be more easily achieved. This results in greatly reduced risk of pushing out bricks when installing in masonry cavities using wet mortar, which can speed up installation and progress on site.
NVFB-LD has been tested to EN 1366-4:2021 and can provide up to 120 minutes integrity and 60 minutes insulation fire resistance performance. It is designed and tested for installation within masonry cavities up to 300 mm wide to reinstate the fire resistance performance of the cavity. Consult manufacturer for full fire resistance performance based on cavity widths and orientation.
Features and benefits:
Color | Beige |
Material | Stonewool Mineral wool |
Shape | Rectangle |
Length | 1200 mm |
Width | Bespoke Guidance for specification option: To suit cavity size:
Manufacturer guidanceIncluding 5 mm compression. |
Height | 100 mm Manufacturer guidanceThickness. |
Uniclass | |
CAWS | P12/40 Mineral wool rigid batts P12/360 Mineral wool rigid batts |
SKU Code | NVFB-LD |
Classification data | |
Material | |
Standard | To BS EN 13162. |
Type | Semi-rigid (compressible). |
Facing | Stone wool. |
Fire performance | Up to 120 minutes integrity and 60 minutes insulation fire resistance performance to EN 1366-4. Guidance for specification option: Dependent on cavity size and wall construction. Consult manufacturer's literature for more information. |
Reaction to fire | To EN 13501-1, Euroclass A1. Guidance for specification option: Does not change with time against heat, weathering, ageing/degradation. |
Length | 1200 mm. |
Thickness | 100 mm. |
Width | 15–80 mm. Guidance for specification option: Includes 5 mm compression. Manufacturer guidanceTo suit cavity size. |
Fastener | Screws. |
Weight | Manufacturer's standard. Guidance for specification option: Dependent on size, to suit cavity width. |
ThermalConductivity | To EN 13162, λ= 0.035 W/(m·K). Guidance for specification option: Does not change with time against heat, weathering, ageing/degradation. |
Orientation | Vertical. Horizontal. |
Contains Red List materials | No |
Material | Stonewool Mineral wool |