NBS Source
I'm a manufacturer

Compare variants

Caltech QC Roofing - Waterproofing Membrane
Caltech QC Roofing - Waterproofing Membrane
Caltech QC Roofing - Waterproofing Membrane

Last verified by manufacturer 4 months ago

Alumasc Roofing

Last verified by manufacturer 4 months ago

Alumasc Roofing

Last verified by manufacturer 4 months ago

Alumasc Roofing
Summary
Cold-applied fast curing liquid roofing system, available in a wide range of colours and finishes.
-
-
Application

For external use on flat and pitched roofs. Compatible with all conventional roofing substrates.

Suitable for the following applications:

  • New build.
  • Refurbishment.
  • Cold roofs.
  • Warm roofs (all roofing insulations).
  • Overlay of existing waterproofing systems.
  • Inverted roofs.
  • Buried membrane applications, including hard/ green roofs.
  • Submerged applications.
-
-
Description

Caltech QC High Performance Roofing Systems comprise a rapid curing two-component, cold-applied, fully reinforced PMMA waterproofing solution, insulation boards and air and vapour control layers (AVCL).

The wet-on-wet application with embedded polyester fleece forms a seamless, durable membrane that is rainproof in just 30 minutes. Available in a range of textures and colours, the system is fully adaptable to meet the requirements of individual projects, for use across all building sectors in both refurbishment and new-build roofing and waterproofing projects.

Approvals:

  • BBA Certificate No. 17/5392.
  • Fire classification of BROOF (t4) in accordance with BS EN 13501-5.
-
-
Product certifications
-
-
Color
Blue, Grey, Other
-
-
Finish
Smooth, Textured, Other
-
-
Material
Fleece, Aluminium, Polyester, Glass Fibre, Polyisocyanurate (PIR), Polymethyl methacrylate (PMMA), High density extruded polystyrene (XPS)
-
-
Shape
Formless
-
-
Length
Bespoke
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-
Warranty description
25 year
-
-

Specification

Classification data
Preparation
-
-
-
Horizontal work
Alumasc Primer.
-
-
Skirtings and vertical work
As horizontal work.
-
-
Liquid-applied waterproofing
-
-
-
Type
Caltech QC, 1.0 kg/m².
-
-
Reinforcement
Caltech QC embedment coat, 2.0 kg/m². QC RF110 (polyester reinforcing fleece).
-
-

Additional properties

Insulation
PIR Insulation (type GTF); attached with PU Insulation Adhesive.
Top of board primed with Euroroof SA Primer.
-
-
Colour
Blue Grey (RAL 7031)., Other.
-
-
Application temperature range
0–20°C (winter grade)., 10–35°C (summer grade).
-
-
Fire rating
To BS EN 13501-5, BROOF (t4).
-
-
Third-party certification
British Board of Agrément (BBA) certified 17/5392 Product Sheet 1.
-
-

Sustainability data

Material
Fleece, Aluminium, Polyester, Glass Fibre, Polyisocyanurate (PIR), Polymethyl methacrylate (PMMA), High density extruded polystyrene (XPS)
-
-
Expected Life
25 year
-
-