NBS Source
I'm a manufacturer

Compare variants

CS Louvres Rain Defence Louvre RS-5900
CS Louvres Rain Defence Louvre RS-5900

Verified over a year ago

Construction Specialties (UK) Ltd

Standard frame

Verified over a year ago

Construction Specialties (UK) Ltd

Glazing frame

Summary
Class A rain defence louvres with vertical blades and visible mullions, offering excellent protection against wind-driven rain penetration and very good airflow. Classified as A 2 up to 3.5 m/s.
Class A rain defence louvres with vertical blades and visible mullions, offering excellent protection against wind-driven rain penetration and very good airflow. Classified as A 2 up to 3.5 m/s.
Color
Silver, Other
Silver, Other
Finish
Mill, Anodized, Powder-coated
Mill, Anodized, Powder-coated
Material
Aluminium
Aluminium
Length
130 mm
130 mm
Width
Bespoke
Bespoke
Height
Bespoke
Bespoke

Specification

Material
All components to be one-piece members extruded from aluminium alloy 6063-T6 (nominal minimum thickness to be: 2.03 mm for heads, cills, jambs and mullions, 1.52 mm for blades).
All components to be one-piece members extruded from aluminium alloy 6063-T6 (nominal minimum thickness to be: 2.03 mm for heads, cills, jambs and mullions, 1.52 mm for blades).
Finish
Milled., Anodized, clear., Anodized, colour., Polyester powder-coated finish, matt, colour., Polyester powder-coated finish, gloss, colour.
Milled., Anodized, clear., Anodized, colour., Polyester powder-coated finish, matt, colour., Polyester powder-coated finish, gloss, colour.
Colour
As Finish.
As Finish.
Construction
Supplied as modules, mechanically assembled in the factory using stainless steel fasteners. Multiple module installations to include interlocking visible mullions with drainage channels.
Supplied as modules, mechanically assembled using stainless steel fasteners, and complete with 25 mm captured glazing frame for direct fitting into glazing sockets.
Weather performance
-
-
Water penetration class (minimum)
To BS EN 13030, class A up to 3.5 m/s.
To BS EN 13030, class A up to 3.5 m/s.
Discharge loss coefficient (minimum)
To BS EN 13030, class 2: Airflow coefficient Ce (entry): 0.342; Cd (discharge): 0.352.
To BS EN 13030, class 2: Airflow coefficient Ce (entry): 0.342; Cd (discharge): 0.352.
Louvre configuration
-
-
Number of banks
One.
One.
Blade orientation
Vertical.
Vertical.
Blade pitch
38 mm.
38 mm.
Blade angle
Complex extruded blade profile.
Complex extruded blade profile.
Accessories
None., Bird/ vermin guard, galvanized steel welded mesh., Bird/ vermin guard, expanded aluminium welded mesh., Insect mesh, PVC-coated fibreglass., Louvred door(s)., Dampers, high-performance PVC-U, volume control., Dampers, aluminium, volume control., Snap-on cover plate to close-off louvre frame.
None., Bird/ vermin guard, galvanized steel welded mesh., Bird/ vermin guard, expanded aluminium welded mesh., Insect mesh, PVC-coated fibreglass., Louvred door(s)., Dampers, high-performance PVC-U, volume control., Dampers, aluminium, volume control., Snap-on cover plate to close-off louvre frame.

Additional properties

Cill pan
Louvres to be supplied with a full depth cill pan with welded side panels, formed from 2 mm-thick aluminium.
-
Blanking panels
Not required., Single-skin aluminium panels, to match louvre., Single-skin aluminium panels, mill finish., Single-skin aluminium panels, other colour/ finish., Insulated panels incorporating A1-classified non-combustible stone wool core., Insulated panels, extruded polystyrene core.
Not required., Single-skin aluminium panels, to match louvre., Single-skin aluminium panels, mill finish., Single-skin aluminium panels, other colour/ finish., Insulated panels incorporating A1-classified non-combustible stone wool core., Insulated panels, extruded polystyrene core.
Blast resistance
Required., Not required.
Required., Not required.