NBS Source
I'm a manufacturer
Compare variants

Vulcan R0.2 Thermal Break

Verified by manufacturer over a year ago

Vulcan R0.2 TB Pads

TBA Firefly Variant:

Thermal Break that reduces the impact of thermal bridging by reducing the flow of heat through the conductive pathway from the steel framing to the external cladding.

Jump to:
+61754114209 Website

Application

Suitable for use in framed wall that have a higher thermal conductivity that cause heat leakage through the wall frame and into the building.

Description

The National Construction Code (BCA Vol 1 & 2) introduced a requirement in 2006 which states that all metal framed buildings of certain construction and building classification, require a Thermal Break with an R 0.2m2 K/W to be installed between the metal frame and external cladding. 

 

Where a Thermal Break is used to meet the compliance provisions of the BCA (NCC) for Metal Framed External Walls of All Type A and Type B Construction it must meet all of the following criteria: 

  • Be a Non-combustible product.  
  • Be installed between the Metal Frame and the External Cladding.  
  • Be a material with an R-Value of not less than R 0.2.  

  

The TBA Firefly Vulcan R0.2 Thermal Break is 100% Non-combustible in accordance with AS1530.1    

General information

Warranty description

25 year

Uniclass

Pr_35_90_87_42 Isolating tapesPrimary

NATSPEC National Classification System

0182 Fire-Stopping

SpeedSpec

07810 Fireproofing

SpecPack

07810 Fireproofing

Specification data - Isolating tapes

Size

10 000 l x 90 w (mm).

Guidance for specification option:

100 mm including Stitch line x 6 mm thick.

Maybe cut into pads, minimum 150 mm length using a long-bladed knife.

Width

90 mm.

Length

150 mm.

R-Value

RO. 26

Fire testing - non combustibility

To AS 1530.1.

Manufacturer guidance

No fillers, no binders and no adhesives.