- Can be used for walls, primarily on sheds and garage walling applications.
- Complements the TRIMDEK® roofing profile.
- Equally suitable for domestic, industrial and commercial applications.
- Can be pierce-fixed to timber or steel supports.
- Suitable only for non-cyclonic areas.
AUSTRALIAN STANDARDS
Published load capacity data is derived from testing in accordance with:
- AS 4040.0 – 1992
- AS 4040.1 – 1992
- AS 4040.2 – 1992
- AS 4040.3:2018
Published Limit state capacities are suitable to determine structural adequacy and serviceability in accordance with:
- AS/NZS 1170.0:2002 Structural design actions, Part 0: General principles –
- AS/NZS 1170.1:2002 (Reconfirmed 2016) Structural design actions, Part 1: Permanent, imposed and other actions –
- AS/NZS 1170.2:2011 (Reconfirmed 2016) Structural design actions, Part 2: Wind actions –
- AS/NZS 1170.3:2011 (Reconfirmed 2016) Structural design actions, Part 3: Snow and ice actions.
Published installation guidelines align with AS 1562.1:2018 Design and Installation of sheet and wall cladding
Lysaght steel products comply with:
- AS 1397-2011 Continuous hot-dip metallic coated steel sheet and strip - Coatings of zinc and zinc alloyed with aluminium and magnesium –
- AS/NZS 2728:2013 Prefinished/prepainted sheet metal products for interior/exterior building applications - Performance requirements –
- AS 1397-2011 which defines the coating types and classes and steel grades for hot dip metallic coated steel.