NBS Source
I'm a manufacturer

Kensa Q Ground Source Heat Pump

Verified by manufacturer 5 months ago

Kensa Group

Large ground source heat pump with A++ energy-related product (ErP) rating.

Jump to:
BOS
+44 (0)345 222 4328 Website

Application

Suitable large or commercial buildings.

Description

The Kensa Q80 Series Heat Pump is designed to provide a low cost renewable heat source for a building’s heating system and will generate significantly lower carbon emissions and running costs compared with traditional fossil fuels.


Kensa Q80 Series Heat Pumps are available with an output of 83kW, and are of a modular design meaning by combining them much higher loads can be achieved.


Features and benefits:

  • Modular design.
  • Low running costs.
  • A++ energy-related product (ErP) rating (based on average climate @35℃).
  • Low carbon emissions.
  • Heating and external cooling options.
  • UK manufactured.
  • Internal vibration eliminators.

General information

Color

Grey

Material

Steel

Shape

Rectangle

Length

1418 mm

Guidance for specification option:

Depth.

Width

755 mm

Height

1718 mm

Warranty description

Two year

Guidance for specification option:

Controller and water pumps.

Five year

Guidance for specification option:

Core heat pump unit (refrigeration components).

Uniclass

Pr_70_60_37_36 Ground source heat pumpsPrimary

CAWS

T90/525 Ground heat exchangers

T90/525 Ground heat exchangers

Specification data - Ground source heat pumps

Loop depth

Guidance for specification option:

Consult manufacturer and insert requirements.

Pipe diameter

50 mm.

Borehole diameter

Guidance for specification option:

Consult manufacturer and insert requirements.

Thermal

83 kW.

Power consumption

20.5 kW.

CoefficientOfPerformance

To EN 14511, 3.94.

Flowrate

359 L/min (brine); 240 L/min (heating water).

Guidance for specification option:

  • Brine (primary) based on 0℃ in, -4℃ out.
  • Heating water (secondary) based on 30℃ in, 35℃ out.

PressureDrop

46.3 kPa (brine); 27.6 kPa (heating water).

Guidance for specification option:

  • Brine (primary) based on 0℃ in, -4℃ out.
  • Heating water (secondary) based on 30℃ in, 35℃ out.

WaterInletTemperatureRange

-5℃ to 15℃.

Manufacturer guidance

Min–max inlet temperature.

Heating secondary flow temperature (UFH)

64℃.

RatedVoltage

380–420 V, 50 Hz.

Power supply

65 A.

Manufacturer guidance

Rating amps.

RatedCurrent

64 A.

Manufacturer guidance

Max amps.

Process medium

R407C.

InternalRefrigerantVolume

6.8 kg.

Compressor

Twin scroll.

Dimensions

1718 x 755 x 1418 mm.

Dry weight

665 kg.

Rating

A++.

Guidance for specification option:

Performance (based on Average Climate) @35℃.

Manufacturer guidance

ErP.

Overall sound power level

72.3 dB (A).

Sustainability data

Country of product manufacture

United Kingdom

Recyclability

Disposal/Decommissioning

Kensa offer a life time decommissioning service for this product. This is available on a return to base basis
(carriage at users cost).

Disposal of any antifreeze water mix should follow the disposal instructions as laid out on the COSH Safety
Data Sheet in the Installation Manual.

This symbol on the product indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the company where this product was purchased.

Returning products
Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Kensa Heat Pumps they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous.

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Literature

TI - Q80 Series Heat Pumps – 1.8

TI - Q80 Series Heat Pumps – 1.8

Q80 Series Heat Pumps Installation and Commissioning Manual

Q80 Series Heat Pumps Installation and Commissioning Manual

Q80 Series Heat Pump Operational Instructions

Q80 Series Heat Pump Operational Instructions

Q80 Installation & Operation Manuals

Q80 Installation & Operation Manuals

Similar products from Kensa Group

Kensa Evo Ground Source Heat Pump

Kensa Evo Ground Source Heat Pump

Kensa Shoebox Ground Source Heat Pump

Kensa Shoebox Ground Source Heat Pump

Kensa Shoebox NX Heat Pump

Kensa Shoebox NX Heat Pump